- Home
- /
- Electrical Supplies
- /
- Power Quality & Distribution
- /
- Power Systems
- /
- Uninterruptible Power Supplies (UPS)
- /
- UPS System, 330 VA, 4 Outlets, Tower/Wall, Out: 120V AC , In:120V AC
Tripp Lite
UPS System, 330 VA, 4 Outlets, Tower/Wall, Out: 120V AC , In:120V AC
Mfr # OMNISMART350HG
Zoro # G3233246
Free Shipping & Returns
$592.99
Item successfully saved to ''
Free Shipping on orders over $50
after youÂ
Free 30-Day Returns
Key Features
- UPS Type Line Interactive
- Power Rating 330 VA
- Mounting Tower/Wall
- Wattage 225 W
- Input Voltage 120V AC
Customers Also Purchased
- Brand Tripp Lite
- MFR # OMNISMART350HG
- Zoro # G3233246
- UPC # 037332098542
- Country of Origin China
- Category Uninterruptible Power Supplies (UPS)
Dimensions
Width | 5 in |
Cord Length | 6 ft |
Height | 11 in |
Depth | 7 in |
UPS Power Module Dimensions (hwd, in.) | 10.8 x 5.2 x 7.2 |
Primary UPS Depth (mm) | 183 |
UPS Input Cord Length (ft.) | 6 |
Primary UPS Height (mm) | 274 |
Primary UPS Width (mm) | 132 |
Details
Item | UPS System |
UPS Type | Line Interactive |
Power Rating | 330 VA |
Mounting | Tower/Wall |
Wattage | 225 W |
Input Voltage | 120V AC |
Output Voltage | 120V AC |
Backup Time (Half/Full Load) | 46 min/18 min |
Outlet Type | UPS/Surge |
Medical Grade | Yes |
Number of Outlets | 4 |
Green Environmental Attribute | Product Contributes To Reducing Energy Consumption |
Special Features | Poweralert Software, Voltage Regulation |
Automatic Volts Regulation | Yes |
Display Type | LED |
NEMA Plug Configuration | 5-15p |
NEMA Receptacle Configuration | 5-15R |
Fax/Modem Line Protection | Yes |
Input Current | 2.3 A |
Phase | 1 |
Includes | Serial Cable for Remote Monitoring |
Ports | DB9 Serial |
Hz | 60 Hz |
Transfer Time | 2 to 4 msec |
Standards | UL 1778; CSA; FCC Part 15 Category B (EMI); UL60601-1 (medical grade) |
Footnotes | 3,6,14 |
Green Certification or Other Recognition | UL1778 (USA, Series AGOM350KSR57HG), UL2601-1 (Medical), cUL (Canada), FCC Class B (emissions), FCC Part 68 / Industry of Canada (telecommunications), Conforms to IEEE 587 / ANSI C62.41 specifications |
Capacity - Batteries | 330 VA/225 W |
Operating Temp. Range | 104°F (40°C) |
Battery Type | Sealed Lead Acid (SLA) |
Input Connection | 6 ft Cord with NEMA 5-15P-HG Plug |
Output Volt Amp Capacity (VA) | 330 |
UPS Input Connection Type | 5-15P-HG |
Output Receptacle Details | Hospital grade output receptacles |
AC Mode BTU / Hr. (Full Load) | 48.8 |
Frequency Compatibility | 60 Hz |
Battery Recharge Rate (Included Batteries) | Less than 4.5 hours from 10% to 90% |
Battery Mode BTU / Hr. (Full Load) | 215.8 |
Primary Form Factor | Tower |
Internal UPS Replacement Battery Cartridge | RBC52 (quantity 2) |
Recommended Electrical Service | 15A 120V |
UPS Dataline Suppression | 2 line TEL/DSL |
Alarm Cancel Operation | Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status |
Output AC Waveform (Battery Mode) | PWM sine wave |
PowerAlert Software | For local monitoring via the UPSâ„¢s built-in communication ports , download PowerAlert Local software at http://www.tripplite.com/poweralert |
Expandable Runtime | No |
Nominal Input Voltage(s) Supported | 120V AC |
UPS AC Suppression Response Time | Instantaneous |
Output Watt Capacity (Watts) | 225 |
Installation Form Factors Supported with Optional Accessories | Wallmount (UPSWM - tower mounting kit) |
Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 89 |
Output Receptacles | (4) 5-15R |
DC System Voltage (VDC) | 12 |
Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
Communications Cable | DB9 serial cable included |
High Availability UPS Features | Hot swappable batteries |
Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
Low Voltage Transfer to Battery Power (Setpoint) | 89 |
Input Phase | Single-Phase |
Relative Humidity | 0 to 95%, non-condensing |
Audible Alarm | Audible alarm indicates power-failure and low-battery conditions |
UPS Housing Material | PVC |
AC Mode Efficiency Rating (100% Load) | 0.94 |
EMI / RFI AC Noise Suppression | Yes |
Output Voltage Regulation (Line Mode) | -18%, +8% |
High Voltage Transfer to Battery Power (Setpoint) | 139 |
Battery Access | Battery access door |
Battery Replacement Description | Hot-swappable, user replaceable batteries |
LED Indicators | 4 LEDs indicate line power, battery power, overload and battery low/replace status |
Communications Interface | DB9 Serial |
Installation Form Factors Supported with Included Accessories | Tower |
Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
Input Circuit Breakers | 3.5A |
Individually Controllable Load Banks | No |
Undervoltage Correction | Input voltages between 89 and 107 are boosted by 14% |
UPS Certifications | Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category B (EMI); Tested to UL60601-1 (medical grade) |
Rated input current (Maximum Load) | 2.3A |
Output Isolation Transformer | Hospital grade load isolation transformer |
Grounding Lug | Grounding lug |
Output Voltage Regulation (Battery Mode) | +/- 5% |
Nominal Output Voltage(s) Supported | 120V |
Output AC Waveform (AC Mode) | Sine wave |
Package Contents | OmniSmart 350HG UPS, OMNI SMART 350HG Hospital Grade UPS System, Serial cable for remote monitoring, Warranty information, Instruction manual |
Typical Battery Recharge Time | 4 Hour |
Certifications & Standards | UL1778 (USA, Series AGOM350KSR57HG), UL2601-1 (Medical), cUL (Canada), FCC Class B (emissions), FCC Part 68 / Industry of Canada (telecommunications), Conforms to IEEE 587 / ANSI C62.41 specifications |
Form Factor | Tower |
Product Line | OmniSmart |
Battery Chemistry | Lead Acid |
Load Capacity | 330 VA/225 W |
Receptacle Detail | 4 x NEMA 5-15R |
Additional Information | Ideal UPS protection for applications in medical patient-care areas where UL2601-1 listed electrical medical equipment is required, Maintains less than 300 microamps leakage current for UPS and all connected equipment, Line-interactive voltage regulation corrects brownouts as low as 83V without using battery power, Hospital-grade plug and outlets offer added degree of safety and reliability to input/output connections, Full line isolation prevents shock potential and operational problems in sensitive electronic equipment, Resistant to electrostatic discharge, Supports loads up to 330VA / 225 watts, 46 minutes half load runtime (with 165VAload), 18 minutes full load runtime (with 330VA load), 4 protected hospital-grade outlets; 6-ft. cord, 1-DB9 serial port for network interface; SNMP compatible, Complete surge protection, line isolation and EMI/RFI noise filtering, 2 phone line surge suppression for modems, fax machines and other phone accessories, 2 year product warranty, Complete remote monitoring cabling included, PowerAlert UPS managment software available via free download, 4 diagnostic LEDs indicate AC present, on battery, voltage correction & battery low/replace, Battery replacement door, Grounding lug |
Network Management | SNMP Manageable |
Plug/Connector Type | NEMA 5-15P |
Battery Life | 6 Year |
Status Indicators | Includes 4 front-panel status indicator LEDs for line power, battery power, voltage regulation and battery low/replace status |
Product Name | OmniSmart 350HG UPS |
Alarm | On Battery |
Maximum Operating Temperature | 104°F (40°C) |
Product Compliance | FCC Part 15 Class B (USA) |
Grounding Details | Grounding lug |
Package Includes | OMNI SMART 350HG Hospital Grade UPS System;Serial cable for remote monitoring;Warranty information;Instruction manual |
Product Certifications | CSA (Canada); UL 1778; UL 60601-1 |
Output Capacity (VA) | 330 |
UPS Applications | Hospital/Medical |
Battery Mode Heat Dissipation (BTU/Hr) @ Half Load | 78.3 |
Battery Mode Heat Dissipation (BTU/Hr) @ Full Load | 215.8 |
Output Capacity (Watts) | 225 |
Description
UPS System, Line Interactive, Power Rating 330 VA, Wattage 225 W, Input Voltage 120V AC, Output Voltage 120V AC, Backup Time (Half/Full Load) 46 min/18 min, Mounting Tower/Wall, Outlet Type UPS/Surge, Number of Outlets 4, Medical Grade Yes, NEMA Receptacle Configuration 5-15R, NEMA Plug Configuration 5-15P, Automatic Volts Regulation Yes, Fax/Modem Line Protection Yes, Transfer Time 2 to 4 msec, Width 5 in, Depth 7 in, Height 11 in, Cord Length 6 ft, Display Type LED, 60 Hz Hz
Documents & Resources
- Hazardous material
3 Reasons You Can Count On Us
-
Supplies for every job.
10 million items and the exact one you need.
-
When you need it fast, count on Zoro!
2 million products ship in 1 day.
-
Stretch your budget further.
Everyday low prices on the brands you love.
Explore More Products
- EATON BUSSMANN DIN Rail Adapter, DRA, Lexan 141 (DRA-1)
- SIEMENS Plug-In Relay, 120V AC Coil Volts, 1 Pin, DPDT (3TX7130-0RF13)
- EATON Proximity Sensor Head, Side Sense, 24mm (E51DS5)
- KABLE KONTROL Kable Kontrol® Corrugated Split Wire Loom Tubing - 1/4" Inside Diameter - 250 Ft - Black (WL901-BK-250)
- TRIPP LITE Smart UPS, 3 kVA, 9 Outlets, Rack/Tower, Out: 120V AC , In:120V AC (SMART3000RM2U)
- TRIPP LITE UPS System, 500 VA, 6 Outlets, Tower, Out: 115/120V AC , In:120V AC (OMNISMART500)
- TRIPP LITE UPS System, 3 kVA, 10 Outlets, Rack, Out: 120V AC , In:120V AC (SMART3000VS)
- TRIPP LITE Smart Lcd 1500Va 2U Rack/Tower Line-Interactive 120V Ups w/ Lcd (SMART1500LCD)
- TRIPP LITE UPS System, 1.5 kVA, 6 Outlets, Rack, Out: 100/110/115/120/127V AC , In:100/115/120/127V AC (SU1500XLCD)
- TRIPP LITE Smart UPS, 1 kVA, 8 Outlets, Tower, Out: 115/120V AC , In:120V AC (Smart1000LCD)
- APC 1500VA Smart UPS LCD 120V, SMT1500C (SMT1500C)
- Tripp Lite Uninterruptible Power Supplies (UPS)