- Item
- Force
- AC Contact Rating - Relay
- 1 A AC-15, 3 A AC-1, 3 A AC-15, 5 A AC-1
- DC Contact Rating - Relay
- 5 A DC-1; 3 A DC-13; 3 A DC-1; 1 A DC-13
- Mounting - Relay
- DIN Rail
- Input Power Consumption (Burden)
- 2 W
- Delay Time - Relay
- Sync time between inputs: 0.5s 2s 4 s
- Mounting Style
- DIN Rail
- For Use With
- Emergency Stop, Guard Switch, Magnetic Switch, PNP Sensors, Proximity Safety Switch, RFID Safety Switch, Safety Light Curtain, Two Hand Control Station or Enabling Switch
- Standards
- CCC, cULus Listed, EAC, IEC 60947-5-1, IEC 61508-1/2/3, IEC 62061, ISO 13849-1, TUV Certified
- Response Time
- 20 msec
- IP Rating
- IP20; IP40; IP54
- Environmental Protection
- Dust & Splash Resistant
- Power Consumption
- 2 W
- Application
- Emergency Stop
- Input Voltage
- 24V AC/DC
- Electrical Connection - Relay
- Screw Terminal, Terminal Block Removable
- Weight
- 7.05 oz
- Delay Type
- Adjustable
- Frequency
- 50/60 Hz
- Delay Time
- 0.5 sec, 2 sec, 4 sec
- Safety Reliability Data
Dcavg Greater Than= 99% Conforming to ISO 13849-1, HFT = 1 Conforming to IEC 61508-1, HFT = 1 Conforming to IEC 62061, MTTFd Greater Than 30 years Conforming to ISO 13849-1, PFHd = 1.13E-09 Conforming to IEC 61508-1, PFHd = 1.13E-09 Conforming to IEC 62061, PFHd = 1.13E-09 Conforming to ISO 13849-1, SFF Greater Than 99% Conforming to IEC 61508-1, SFF Greater Than 99% Conforming to IEC 62061, Type = B Conforming to IEC 61508-1
- Maximum Operating Temperature
- 185 Degrees F
- Number of Inputs
- 2
- Contact Rating (AC)
- 1 A @ 15V (NC), 3 A @ 1V (NC), 3 A @ 15V (NO), 5 A @ 1V (NO)
- Number of Input Channels
- 2
- Electrical Connection
- Screw Terminal, Terminal Block Removable
- Minimum Operating Temperature
- -13 Degrees F
- Contact Rating (DC)
- 1 A @ 13V (NC), 3 A @ 1V (NC), 3 A @ 13V (NO), 5 A @ 1V (NO)
- [Ith] Conventional Free Air Thermal Current
- 8A
- Mounting Support
- 35 mm symmetrical DIN rail
- Connections - Terminals
removable screw terminal block, 0.2...2.5 mm² solid or flexible || removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor || removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor || removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel || removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
- Product Or Component Type
- safety module
- Input/Output Type
- semiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related
- [Ui] Rated Insulation Voltage
- 250 V 2)EN/IEC 60947-1
- Power Consumption In Va
- 5.0 VA 24 V AC 50/60 Hz
- Auxiliary Contact Composition
- 2 NO
- Ip Degree Of Protection
- IP20 terminals)EN/IEC 60529 || IP40 housing)EN/IEC 60529 || IP54 mounting area)EN/IEC 60529
- Minimum Output Voltage
- 12 V relay output
- Local Signalling
- for power ON LED (green) || for error LED (red) || for safety output status LED (yellow) || for start input LED (yellow) || for safety input S12 LED (yellow) || for safety input S13 LED (yellow) || for safety input S22 LED (yellow) || for safety input S23 LED (yellow)
- Electrical Circuit Type
- NC pair || PNP pair || antivalent pair || OSSD pair
- Power Consumption In W
- 2 W 24 V DC
- Maximum Response Time On Input Open
- 20 ms
- Safety Module Application
- for electrical monitoring of two-hand control stations || monitoring antivalent contacts || for emergency stop, guard and light curtain monitoring || for enabling switch monitoring
- Safety Module Name
- XPSUS
- Safety Level
- can reach PL e/category 4 ISO 13849-1 || can reach SILCL 3 IEC 62061 || can reach SIL 3 IEC 61508
- Synchronisation Time Between Inputs
- 0.5 s || 2 s || 4 s
- Maximum Line Resistance
- 500 Ohm
- Ambient Air Temperature For Storage
- -25-85°C
- Product Certifications
- TUV || cULus
- Input Protection Type
- internal, electronic
- Function Of Module
emergency stop button with 2 NC contacts || guard monitoring with 1 or 2 limit switches || monitoring 2 PNP sensors || magnetic switch monitoring || light curtain monitoring || RFID switch || monitoring of electro-sensitive protection equipment (ESPE) || enabling switch monitoring || proximity sensor monitoring || monitoring two-hand control station
- Associated Fuse Rating
- 10 A gG NO relay output circuit IEC 60947-1
- Input Compatibility
normally closed circuit ISO 14119 || XC limit switch ISO 14119 || mechanical contact ISO 14119 || normally closed circuit ISO 13850 || antivalent pair ISO 14119 || OSSD pair IEC 61496-1-2 || two-hand control EN 574/ISO 13851-III A || two-hand control EN 574/ISO 13851-III C || 3-wire proximity sensors PNP
- [Ie] Rated Operational Current
5 A AC-1 for normally open relay contact || 3 A AC-15 for normally open relay contact || 5 A DC-1 for normally open relay contact || 3 A DC-13 for normally open relay contact || 3 A AC-1 for normally closed relay contact || 1 A AC-15 for normally closed relay contact || 3 A DC-1 for normally closed relay contact || 1 A DC-13 for normally closed relay contact
- [Uimp] Rated Impulse Withstand Voltage
- 4 kV II EN/IEC 60947-1
- Relative Humidity
- 5-95 % non-condensing
- Number Of Outputs
- 3 on/off configurable pulsed output
- [Us] Rated Supply Voltage
- 24 V AC - 15...10 % || 24 V DC - 20...20 %
- Type Of Start
- automatic/manual/monitored
- Minimum Output Current
- 10 mA relay output