- Item
- IEC Magnetic Contactor
- Auxiliary Contact Form
- 1NC
- Coil Voltage
- 110V AC
- Number of Poles
- 3
- Full Load Amps-Inductive
- 12 A
- Full Load Amps-Resistive
- 20 A
- Reversing Capability
- Reversing
- Terminal Connection Type
- Screw Clamp
- Number of Auxillary Contacts
- 1
- Standards
- EN/IEC 60947-4-1, GB/T 14048.4, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, CB Scheme, CCC, UL, CSA, EAC, CE, UKCA, TC IEC 60068, TC DIN 50016
- Series
- LC2K
- Features
- Preassembled with Reversing Power Busbar
- Application
- Motor Control, Resistive Load
- Electrical Durability
- 0.3 Mcycles (20 A, AC-1, Less than 440 V); 1.3 Mcycles (12 A, AC-3, Less than 440 V); 1.3 Mcycles (12 A, AC-3e, Less than 440 V)
- Watts Loss
- 1.3W
- Rated Insulation Volts
- 600/690V
- Max. Operating Watts
- 4 kW (at 480V AC 50/60 Hz), 4 kW (at 500 to 600V AC 50/60 Hz), 4 kW (at 660 to 690V AC 50/60 Hz), 3 kW (at 220 to 230V AC 50/60 Hz), 5.5 kW (at 380 to 415VAC 50/60 Hz), 5.5 kW (at 440V AC 50/60 Hz)
- Mechanical Durability
- 5 Mcycles
- Operating Time
- 10 to 20 ms (Coil Energisation and NO Closing), 10 to 20 ms (Coil De-Energisation and NO Opening)
- Vibration Resistance
- 4 G (Contactor Closed), 2 G (Contactor Open)
- Fuse Amps
- 25 A (Power Circuit), 10 A (Signalling Circuit)
- Impulse Withstand Voltage
- 8 kV
- Rated Making Capacity
- 144 A @ 690V (AC Power Circuit), 110 A (AC Signalling Circuit)
- Control Circuit Voltage Limits
- Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C)
- Shock Resistance
- 10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open)
- Operating Speed
- 3600 cycles per hr
- Insulation Resistance Range
- Greater Than 10 MOhms (Signalling Circuit)
- Environmental Attributes
- Mercury Free, Toxic Heavy Metal Free
- Signalling Circuit Frequency
- Less Than 400 Hz
- Switching Current
- 5 mA (Signalling Circuit)
- Overvoltage Category
- CAT III
- Net Weight
- 0.39 kg
- Fire Rating
- UL 94 V1, NF F 16-101, NF F 16-102
- IP Rating
- IP20
- Rated Short-Time Withstand Current
115 A (at 50 Degrees C for 1 s Power Circuit), 105 A (at 50 Degrees C for 5 s Power Circuit), 100 A (at 50 Degrees C for 10 s Power Circuit), 75 A (at 50 Degrees C for 30 s Power Circuit), 55 A (at 50 Degrees C for 1 min Power Circuit), 50 A (at 50 Degrees C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 25 A (at 50??C for 15 min Power Circuit)
- Inrush VA
- 30 VA
- Impedance
- 3 mOhm
- Tightening Torque
- 0.8 to 1.3 Nm
- Rated Breaking Capacity
- 110 A @ 440V, 80 A @ 500V, 70 A @ 660 to 690V
- Switching Voltage
- 17 V (Signalling Circuit)
- Hold VA
- 4.5 VA
- Full Load Current - Resistive
- 20 A
- Full Load Current - Inductive
- 12 A
- Mounting Style
- Plate, Rail
- Maximum Voltage Rating
- 690V AC
- Conventional Free Air Thermal Current
- 20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit)