- Item
- IEC Magnetic Contactor
- Auxiliary Contact Form
- 1NC/1NO
- Coil Voltage
- 120V AC
- Number of Poles
- 3
- Full Load Amps-Inductive
- 115 A
- Full Load Amps-Resistive
- 200 A
- Reversing Capability
- Reversing
- Terminal Connection Type
- Screw Clamp
- Number of Auxillary Contacts
- 2
- Standards
- CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, BV, CCC, CSA, DNV, GL, RINA, UL, EAC, UKCA, TH IEC 60068-2-30
- Series
- LC2D, TeSys
- HP @ 3 Phase - 575V
- 100 hp
- Application
- Motor Control, Resistive Load
- Features
- Built-In Bi-Directional Peak Limiting Diode Suppressor; Preassembled with Reversing Power Busbar
- Tightening Torque
- 1.2 Nm (Control Circuit), 12 Nm (Power Circuit)
- Insulation Resistance Range
- Greater Than 10 MOhms (Signalling Circuit)
- Rated Breaking Capacity
- 1100 A @ 440V
- Operating Time
- 20 to 50 ms (Closing), 6 to 20 ms (Opening)
- Signalling Circuit Frequency
- 25 to 400 Hz
- Non-Overlap Time
- 1.5 ms
- Fuse Amps
- 10 A (Signalling Circuit), 250 A (Type 1 Power Circuit), 200 A (Type 2 Power Circuit)
- Switching Current
- 5 mA (Signalling Circuit)
- Fire Rating
- UL 94 V1
- Environmental Attributes
- Mercury Free, PVC Free, Pollution Degree 3
- Watts Loss
- 3 to 8W
- Impedance
- 0.6 mOhm
- Inrush VA
- 280 to 350 VA
- Shock Resistance
- 15 G for 11 ms (Contactor Closed), 6 G for 11 ms (Contactor Open)
- Control Circuit Voltage Limits
- Drop-Out AC: 0.3 to 0.5 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.15 Uc (at -40-55°C 50/60 Hz), 1 to 1.15 Uc (at 55-70°C 50/60 Hz)
- Operating Speed
- 2400 cycles per hr
- Vibration Resistance
- 4 G (Contactor Closed), 2 G (Contactor Open)
- Overvoltage Category
- CAT III
- Impulse Withstand Voltage
- 8 kV
- IP Rating
- IP20
- Rated Insulation Volts
- 600/1000V (Power Circuit), 600/690V (Signalling Circuit)
- Electrical Durability
- 0.8 Mcycles (200 A, AC-1, Less than 440 V); 0.95 Mcycles (115 A, AC-3, Less than 440 V)
- Net Weight
- 6.35 kg
- Hold VA
- 2 to 18 VA
- Rated Making Capacity
- 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1260 A @ 440V (Power Circuit)
- Switching Voltage
- 17 V (Signalling Circuit)
- Mechanical Durability
- 8 Mcycles
- Includes Protective Cover
- Yes
- Max. Operating Watts
- 30 kW (at 220 to 230V AC 50 Hz), 55 kW (at 380 to 400V AC 50 Hz), 59 kW (at 415 to 440V AC 50 Hz), 75 kW (at 500V AC 50 Hz), 80 kW (at 660 to 690V AC 50 Hz), 65 kW (at 1000V AC 50 Hz)
- Rated Short-Time Withstand Current
- 250 A (at 40°C for 10 min Power Circuit), 550 A (at 40°C for 1 min Power Circuit), 950 A (at 40°C for 10 s Power Circuit), 1100 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
- Ambient Air Temperature For Operation
- -40-60°C, 60-70°C with derating
- Auxiliary Contacts Type
- mechanically linked 1 NO + 1 NC IEC 60947-5-1, mirror contact 1 NC IEC 60947-4-1
- Ambient Air Temperature For Storage
- -60-80°C
- [Ui] Rated Insulation Voltage
- power circuit 600 V CSA, power circuit 600 V UL, signalling circuit 690 V IEC 60947-1, signalling circuit 600 V CSA, signalling circuit 600 V UL, power circuit 1000 V IEC 60947-4-1
- Control Circuit Type
- AC 50/60 Hz
- [Icw] Rated Short-Time Withstand Current
- 250 A 40°C - 10 min for power circuit, 550 A 40°C - 1 min for power circuit, 950 A 40°C - 10 s for power circuit, 1100 A 40°C - 1 s for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
- Climatic Withstand
- IACS E10
- Power Dissipation Per Pole
- 24 W AC-1, 7.9 W AC-3
- Heat Dissipation
- 3-8 W 50/60 Hz
- Product Name
- TeSys Deca
- Utilisation Category
- AC-1, AC-3, AC-3e
- Contactor Application
- motor control, resistive load
- Maximum Operating Rate
- 2400 cyc/h 60°C
- Interlocking Type
- electrical, mechanical
- Protective Cover
- with
- Protective Treatment
- TH IEC 60068-2-30
- Device Presentation
- preassembled with reversing power busbar
- Fire Resistance
- 850°C IEC 60695-2-1
- Pole Contact Composition
- 3 NO
- Mechanical Robustness
- vibrations contactor open2 Gn, 5...300 Hz, vibrations contactor closed4 Gn, 5...300 Hz, shocks contactor closed15 Gn for 11 ms, shocks contactor open6 Gn for 11 ms
- Operating Altitude
- 0...9842.52 ft (0...3000 m)
- Full Load Current - Inductive
- 115 A
- Horsepower @ Three Phase - 208V AC
- 30 hp
- Horsepower @ Three Phase - 480V AC
- 75 hp
- Horsepower @ Three Phase - 240V AC
- 40 hp
- Full Load Current - Resistive
- 200 A
- Inrush Power in VA
- 280-350 VA 60 Hz 0.8 20°C) , 280-350 VA 50 Hz 0.8 20°C)
- Rated Operational Voltage
- power circuit <= 1000 V AC 25...400 Hz, power circuit <= 300 V DC
- Mounting Style
- Plate, Rail
- Rated Operational Current
- 200 A (at <60°C) at <= 440 V AC AC-1 for power circuit, 115 A (at <60°C) at <= 440 V AC AC-3 for power circuit
- Control Circuit Voltage
- 120 V AC 50/60 Hz
- Maximum Voltage Rating
- 1000V AC, 300V DC
- Maximum Operating Temperature
- 140 Degrees F
- Conventional Free Air Thermal Current
- 200 A (at 60°C Power Circuit)