Shop SCHNEIDER ELECTRIC

IEC Magnetic Contactor, 1NC/1NO, 200V AC, 3 P, Non-Reversing, Screw Clamp

  • Mfr # LC1D50AL7
  • Zoro # G1157003

product price: 
$
284.99
/ea
Free Shipping & Returns

Key Features

Auxiliary Contact Form
1NC/1NO
Coil Voltage
200V AC
Number of Poles
3
Full Load Amps-Inductive
50 A
Full Load Amps-Resistive
80 A
See all product information
Unlock 30-day payment terms
Unlock 30-day payment terms
Business customers can apply for Net 30—no fees, no interest, fast approval. Terms apply.
Create Account
Get 10% off your order
Get 10% off your order
Sign up for our email list and receive your promo code via email.

Specifications

Details

MFR #
LC1D50AL7
Zoro #
G1157003
UPC #
785901565239
Country of Origin
Indonesia
Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Coil Voltage
200V AC
Number of Poles
3
Full Load Amps-Inductive
50 A
Full Load Amps-Resistive
80 A
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UL 508, UL Listed
HP @ 1 Phase - 230V
7-1/2
Reversing
No
HP @ 3 Phase - 575V
40 hp
Enclosure NEMA Rating
No Enclosure
Series
TeSys Deca
Includes
Everlink Power Connections
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Rated Breaking Capacity
900 A @ 440V
Overvoltage Category
CAT III
Electrical Durability
1.45 Mcycles (50 A, AC-3, Less than 440 V); 1.1 Mcycles (80 A, AC-1, Less than 440 V); 1.45 Mcycles (50 A, AC-3e, Less than 440 V)
Net Weight
0.855 kg
Features
Without Built-In Suppressor Module
Rated Short-Time Withstand Current
400 A (at 40°C for 10 s Power Circuit), 810 A (at 40°C for 1 s Power Circuit), 84 A (at 40°C for 10 min Power Circuit), 208 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Max. Operating Watts
15 kW (at 220 to 230V AC 50/60 Hz AC-3), 22 kW (at 380 to 400V AC 50/60 Hz AC-3), 30 kW (at 500V AC 50/60 Hz AC-3), 33 kW (at 660 to 690V AC 50/60 Hz AC-3), 25 kW (at 415V AC 50/60 Hz AC-3), 30 kW (at 440V AC 50/60 Hz AC-3), 11 kW (at 400V AC 50/60 Hz AC-4), 15 kW (at 220 to 230V AC 50/60 Hz AC-3e), 22 kW (at 380 to 400V AC 50/60 Hz AC-3e), 30 kW (at 500V AC 50/60 Hz AC-3e), 33 kW (at 660 to 690V AC 50/60 Hz AC-3e), 25 kW (at 415V AC 50/60 Hz AC-3e), 30 kW (at 440V AC 50/60 Hz AC-3e)
Switching Voltage
17 V (Signalling Circuit)
Application
Motor Control, Resistive Load
Includes Protective Cover
Yes
Control Circuit Voltage Limits
Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Rated Making Capacity
140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 900 A @ 440V (Power Circuit)
Tightening Torque
1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit)
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
IP Rating
IP20
Watts Loss
4 to 5W
Operating Speed
3600 cycles per hr
Rated Insulation Volts
600V, 690V
Fuse Amps
10 A (Signalling Circuit), 100 A (Type 1 Power Circuit), 100 A (Type 2 Power Circuit)
Signalling Circuit Frequency
25 to 400 Hz
Shock Resistance
10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Environmental Attributes
Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Fire Rating
UL 94 V1
Impedance
1.5 mOhm
Operating Time
4 to 19 ms (Opening), 12 to 26 ms (Closing)
Hold VA
13 VA (at 60 Hz 20°C), 15 VA (at 50 Hz 20°C)
Impulse Withstand Voltage
6 kV
Non-Overlap Time
1.5 ms
Switching Current
5 mA (Signalling Circuit)
Inrush VA
140 VA (at 60 Hz 20°C), 160 VA (at 50 Hz 20°C)
Mechanical Durability
6 Mcycles
Contactor Style
IEC
Horsepower @ Single Phase - 240V AC
7 1/2 hp
Full Load Current - Inductive
50 A
Minimum Operating Temperature
-40 Degrees F
Horsepower @ Three Phase - 480V AC
40 hp
NEMA Enclosure Rating
No Enclosure
Resistance Properties
Fire Resistant, Insulation Resistant
Embedded Surge Suppressor
No
Horsepower @ Three Phase - 208V AC
15 hp
Maximum Operating Temperature
140 Degrees F
Maximum Voltage Rating
690V AC
Frequency
50/60 Hz
Mounting Style
DIN Rail, Plate
Electrical Operating Durability
1,100,000, 1,450,000
Full Load Current - Resistive
80 A
Includes Auxiliary Contacts
Yes
Horsepower @ Single Phase - 120V AC
3 hp
Horsepower @ Three Phase - 240V AC
15 hp
Phase
Three
Horsepower @ Three Phase - 600V AC
40 hp
Mechanical Operating Durability
6,000,000
Number of Normally Open Main Contacts
3
Conventional Free Air Thermal Current
10 A (at 60°C Signalling Circuit), 80 A (at 60°C Power Circuit)

Dimensions

Working Height
Up to 9842.52 ft
Overall Width
2.17 in
Overall Height
4.8 in
Overall Depth
4.72 in

Description

Schneider Electric IEC Magnetic Contactor, 3-pole, non-reversing, with a 200 V AC coil and 1 normally open/1 normally closed auxiliary contacts (2 auxiliary contacts total). It is an IEC-style magnetic contactor rated for switching power circuits for motor control and resistive loads, suitable for installation in control panels with standardized sizing.

Action: Non-Reversing

  • Poles: 3; Phase: Three
  • Coil Voltage: 200 V AC
  • Auxiliary Contacts: 2 total (1NO/1NC)
  • Main Contacts: 3 NO
  • Contactor Style: IEC
  • Application: Suitable for motor control and resistive load applications (see specifications).
  • Electrical Connection: Control Circuit: Screw Clamp Terminals; Power Circuit: EverLink BTR Screw Connectors
  • Includes: Power connections and protective cover as specified.
  • IP Rating / Enclosure: Rated at IP20; enclosure not included.
  • Mounting Style / Mounts On: Compatible with DIN rail or mounting plates as specified.
  • Dimensions: Dimensions are provided as approximate measurements based on product specifications.
  • Net Weight: Net weight is approximately 0.855 kg based on manufacturing data.
  • Rated Voltage: Rated voltage ranges are specified within the product's operational ratings (see specifications).
  • Series: Series designation only; does not imply performance guarantees beyond listed standards.
  • Reversing: Reversing function not included or supported by this model specification.
  • Overvoltage Category: Overvoltage category classification per standards but does not guarantee suitability under all conditions outside specified ratings.
  • Frequency: Frequency compatibility within standard operating ranges (see specifications).
  • Rated Making Capacity: Capacities are rated values based on testing conditions but do not imply continuous or guaranteed operation under all circumstances.
  • Rated Short-Time Withstand Current: 400 A (40°C, 10 s); 810 A (40°C, 1 s)
  • Mechanical Durability: 6 Mcycles
  • Electrical Durability: 1,100,000 to 1,450,000 cycles
  • Standards: EN 60947-4-1, EN 60947-5-1, UL 508, UL Listed, CSA, CSA C22.2 No 14
  • Fire Rating: UL 94 V1
  • Holding/Coil VA: 13 VA (60 Hz, 20°C); 15 VA (50 Hz, 20°C)
  • Ratings & reviews

    3 reasons you can count on us

    • Supplies for every job.

      13 million items and the exact one you need.

    • When you need it fast, count on Zoro!

      4.5 million products ship in 1 day.

    • Stretch your budget further.

      Everyday low prices on the brands you love.