IEC Magnetic Contactor, 1NC/1NO, 220V AC, 3 P, Non-Reversing, Screw Clamp

  • Mfr # LC1D65AM7

  • Zoro # G0849698


product price:  $362.99
/ea
Free Shipping & Returns

Key Features

Auxiliary Contact Form
1NC/1NO
Coil Voltage
220V AC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
See all product information
Get a 10% off coupon
Free 30-day returns
Return Policy
Get 30 days to pay with Net 30
Apply Now
Unlock tax-exempt savings
Add Tax Exemption

Specifications

Product Information

MFR #
LC1D65AM7
Zoro #
G0849698
UPC #
785901565659
Country of Origin
Indonesia

Dimensions

Working Height
Up to 9842.52 ft
Overall Depth
120 mm
Overall Width
55 mm
Overall Height
122 mm

Details

Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Coil Voltage
220V AC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, IEC 60335-1, UL, CCC, GOST, CSA, THIEC 60068-2-30
Series
LC1D
Includes
Everlink Power Connections
HP @ 3 Phase - 575V
50 hp
Features
Without Built-In Suppressor Module
IP Rating
IP20
Non-Overlap Time
1.5 ms
Operating Speed
3600 cycles per hr
Rated Insulation Volts
600/690V
Impedance
1.5 mOhm
Watts Loss
4 to 5W
Switching Voltage
17 V (Signalling Circuit)
Includes Protective Cover
Yes
Tightening Torque
1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit)
Impulse Withstand Voltage
6 kV
Fire Rating
UL 94 V1
Switching Current
5 mA (Signalling Circuit)
Hold VA
13 VA (at 60 Hz 20°C), 15 VA (at 50 Hz 20°C)
Rated Short-Time Withstand Current
520 A (at 40°C for 10 s Power Circuit), 900 A (at 40°C for 1 s Power Circuit), 110 A (at 40°C for 10 min Power Circuit), 260 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Environmental Attributes
Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Signalling Circuit Frequency
25 to 400 Hz
Fuse Amps
10 A (Signalling Circuit), 125 A (Type 1 Power Circuit), 125 A (Type 2 Power Circuit)
Rated Making Capacity
140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1000 A @ 440V (Power Circuit)
Application
Motor Control, Resistive Load
Rated Breaking Capacity
1000 A @ 440V
Inrush VA
140 VA (at 60 Hz 20°C), 160 VA (at 50 Hz 20°C)
Net Weight
0.86 kg
Mechanical Durability
6 Mcycles
Max. Operating Watts
11 kW (at 400V AC 50/60 Hz AC-4), 18.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 30 kW (at 380 to 400V AC 50/60 Hz AC-3), 37 kW (at 500V AC 50/60 Hz AC-3), 37 kW (at 660 to 690V AC 50/60 Hz AC-3), 18.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 30 kW (at 380 to 400V AC 50/60 Hz AC-3e), 37 kW (at 500V AC 50/60 Hz AC-3e), 37 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Control Circuit Voltage Limits
Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Shock Resistance
10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Operating Time
4 to 19 ms (Opening), 12 to 26 ms (Closing)
Electrical Durability
1.4 Mcycles (80 A, AC-1, Less than 440 V); 1.45 Mcycles (65 A, AC-3, Less than 440 V); 1.45 Mcycles (65 A, AC-3e, Less than 440 V)
Overvoltage Category
CAT III
Rated Operational Current
80 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 65 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 65 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Protective Cover
With
Contact Compatibility
M2
Inrush Power in VA
140 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 160 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Contactor Application
Motor control; Resistive load
Conventional Free Air Thermal Current
10 A (at 140°F (60°C)) for signalling circuit; 80 A (at 140°F (60°C)) for power circuit
Power Dissipation Per Pole
9.6 W AC-1; 6.3 W AC-3; 6.3 W AC-3e
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Operating Altitude
0 to 9842.52 ft (0 to 3000 m)
Protective Treatment
THIEC 60068-2-30
Control Circuit Voltage
220 V AC 50/60 Hz
Fire Resistance
1562°F (850°C) IEC 60695-2-1
Maximum Operating Rate
3600 cyc/h 140°F (60°C)
Pollution Degree
3
Climatic Withstand
IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat
Rated Operational Voltage
Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
Heat Dissipation
4 to 5 W at 50/60 Hz
Mechanical Robustness
Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor closed 15 Gn for 11 ms); Shocks contactor open 10 Gn for 11 ms)
Pole Contact Composition
3 NO
Control Circuit Type
AC 50/60 Hz standard
Auxiliary Contacts Type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
Utilisation Category
AC-4; AC-1; AC-3; AC-3e
Full Load Current - Inductive
65 A
Horsepower @ Three Phase - 208V AC
20 hp
Full Load Current - Resistive
80 A
Horsepower @ Three Phase - 240V AC
20 hp
Horsepower @ Single Phase - 240V AC
10 hp
Horsepower @ Three Phase - 480V AC
40 hp
Maximum Voltage Rating
690V AC, 300V DC
Ambient Air Temperature For Operation
-40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating
Maximum Operating Temperature
140 Degrees F
Mounting Style
Plate, Rail

Description

The SCHNEIDER ELECTRIC - IEC Magnetic Contactor is a non-reversing, 3-pole contactor with a coil voltage of 220V AC. It's designed for motor control and resistive load applications, featuring mechanically linked auxiliary contacts and an average impedance of 1.5 mOhm. The contactor is designed to meet the requirements of IACS E10 and IEC 60947-1 Annex Q category D standards for damp heat exposure. Its connections include screw clamp terminals for the control circuit and EverLink BTR screw connectors for the power circuit.

Key features include:

  • Auxiliary Contact Form: 1NC/1NO
  • Associated Fuse Rating: Suitable for various circuits conforming to IEC standards.
  • Coil Voltage: Operates at 220V AC.
  • Connections - Terminals: Features both screw clamp terminals and EverLink BTR screw connectors.
  • Electrical Durability: Tested for approximately 1.45 million cycles under specific test conditions.
  • Full Load Amps - Inductive & Resistive: Rated for a maximum of 65A inductive load and up to 80A resistive load.
  • Horsepower Ratings: Dependent on voltage level; highest observed horsepower rating was with three-phase motors operating at voltages between 575/600 V AC (50 hp).
  • Insulation Resistance Range: Greater than or equal to10 MOhms (Signalling Circuit)
  • -Includes Protective Cover
  • -Maximum Operating Rate tested at3600 cyc/h
  • -Rated Operational Current/Voltage : Tested with currents Up to80 A (at Less than140°F)for power circuit; Power circuits rated for operation within690 V AC25to400 Hz range, or within300 V DC range.
  • -Tightening Torque : Control Circuit(1.7 Nm),Power Circuit(2.5to8 Nm).
  • Ratings & Reviews

    3 Reasons You Can Count On Us

    • Supplies for every job.

      Supplies for every job.

      10 million items and the exact one you need.

    • When you need it fast, count on Zoro!

      When you need it fast, count on Zoro!

      2 million products ship in 1 day.

    • Stretch your budget further.

      Stretch your budget further.

      Everyday low prices on the brands you love.