- Item
- IEC Magnetic Contactor
- Auxiliary Contact Form
- 1NC/1NO
- Coil Voltage
- 110V AC
- Number of Poles
- 4
- Full Load Amps-Inductive
- 12 A
- Full Load Amps-Resistive
- 25 A
- Reversing Capability
- Non-Reversing
- Terminal Connection Type
- Screw Clamp
- Number of Auxillary Contacts
- 2
- Standards
- CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, IEC 60335-1, RINA, GL, BV, UL, CSA, CCC, LROS, DNV, GOST, UKCA, THIEC 60068-2-30
- Series
- LC1D
- Vibration Resistance
- 4 G (Contactor Closed), 2 G (Contactor Open)
- Electrical Durability
- 0.8 Mcycles (25 A, AC-1, Less than 440 V)
- Switching Current
- 5 mA (Signalling Circuit)
- Environmental Attributes
- Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
- Signalling Circuit Frequency
- 25 to 400 Hz
- Hold VA
- 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
- Impulse Withstand Voltage
- 6 kV
- Net Weight
- 0.365 kg
- Fuse Amps
- 10 A (Signalling Circuit), 40 A (Type 1 Power Circuit), 25 A (Type 2 Power Circuit)
- Includes Protective Cover
- Yes
- Features
- Without Built-In Suppressor Module
- Fire Rating
- UL 94 V1
- Inrush VA
- 70 VA
- Rated Making Capacity
- 250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
- Operating Time
- 12 to 22 ms (Closing), 4 to 19 ms (Opening)
- Watts Loss
- 2 to 3W
- IP Rating
- IP20
- Insulation Resistance Range
- Greater Than 10 MOhms (Signalling Circuit)
- Overvoltage Category
- CAT III
- Tightening Torque
- 1.7 Nm
- Operating Speed
- 3600 cycles per hr
- Switching Voltage
- 17 V (Signalling Circuit)
- Shock Resistance
- 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
- Rated Breaking Capacity
- 250 A @ 440V
- Mechanical Durability
- 15 Mcycles
- Rated Insulation Volts
- 600/690V
- Non-Overlap Time
- 1.5 ms
- Rated Short-Time Withstand Current
105 A (at 40 Degrees C for 10 s Power Circuit), 210 A (at 40 Degrees C for 1 s Power Circuit), 30 A (at 40 Degrees C for 10 min Power Circuit), 61 A (at 40 Degrees C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
- Control Circuit Voltage Limits
- Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
- Impedance
- 2.5 mOhm
- Application
- Resistive Load
- Mechanical Robustness
- Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor open 10 Gn for 11 ms); Shocks contactor closed 15 Gn for 11 ms)
- Contact Compatibility
- M6
- Safety Reliability Level
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Operating Altitude
- 0 to 9842.52 ft (0 to 3000 m)
- Maximum Operating Rate
- 3600 cyc/h 140°F (60°C)
- Control Circuit Type
- AC 50/60 Hz
- Pole Contact Composition
- 2 NO + 2 NC
- Protective Cover
- With
- Climatic Withstand
- IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat
- Control Circuit Voltage
- 110 V AC 50/60 Hz
- Fire Resistance
- 1562°F (850°C) IEC 60695-2-1
- Pollution Degree
- 3
- Inrush Power in VA
- 70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
- Rated Operational Voltage
- Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
- Auxiliary Contacts Type
- Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
- Conventional Free Air Thermal Current
- 25 A (at 140°F (60°C)) for power circuit; 10 A (at 140°F (60°C)) for signalling circuit
- Rated Operational Current
- 25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit
- Protective Treatment
- THIEC 60068-2-30
- Heat Dissipation
- 2 to 3 W at 50/60 Hz
- Utilisation Category
- AC-1; AC-3; AC-3e; AC-4
- Power Dissipation Per Pole
- 1.56 W AC-1
- Full Load Current - Resistive
- 25 A
- Full Load Current - Inductive
- 12 A
- Mounting Style
- Plate, Rail
- Maximum Operating Temperature
- 140 Degrees F
- Maximum Voltage Rating
- 690V AC, 300V DC
- Ambient Air Temperature For Operation
- -40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating