IEC Magnetic Contactor, 1NC/1NO, 240V AC, 3 P, Non-Reversing, Screw Clamp

  • Mfr # LC1D25U7

  • Zoro # G0492301


product price:  $177.99
/ea
Free Shipping & Returns

Key Features

Auxiliary Contact Form
1NC/1NO
Coil Voltage
240V AC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
See all product information
Get a 10% off coupon
Free 30-day returns
Return Policy
Get 30 days to pay with Net 30
Apply Now
Unlock tax-exempt savings
Add Tax Exemption

Specifications

Product Information

MFR #
LC1D25U7
Zoro #
G0492301
UPC #
785901207177
Country of Origin
Indonesia

Dimensions

Working Height
Up to 9842.52 ft
Overall Height
3.35 in
Overall Depth
3.62 in
Overall Width
1.77 in

Details

Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Coil Voltage
240V AC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
HP @ 1 Phase - 230V
3
Frame / Series / Class / Code
TeSys
Enclosure NEMA Rating
No Enclosure
Reversing
No
HP @ 3 Phase - 575V
20 hp
Series
TeSys Deca
IP Rating
IP20
Signalling Circuit Frequency
25 to 400 Hz
Impulse Withstand Voltage
6 kV
Fire Rating
UL 94 V1
Inrush VA
70 VA
Features
Without Built-In Suppressor Module
Shock Resistance
8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Tightening Torque
1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit)
Control Circuit Voltage Limits
Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Operating Speed
3600 cycles per hr
Rated Insulation Volts
600/690V
Application
Motor Control, Resistive Load
Fuse Amps
10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 40 A (Type 2 Power Circuit)
Mechanical Durability
15 Mcycles
Max. Operating Watts
5.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 11 kW (at 380 to 400V AC 50/60 Hz AC-3), 11 kW (at 415 to 440V AC 50/60 Hz AC-3), 15 kW (at 500V AC 50/60 Hz AC-3), 15 kW (at 660 to 690V AC 50/60 Hz AC-3), 5.5 kW (at 400V AC 50/60 Hz AC-4), 5.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 11 kW (at 380 to 400V AC 50/60 Hz AC-3e), 11 kW (at 415 to 440V AC 50/60 Hz AC-3e), 15 kW (at 500V AC 50/60 Hz AC-3e), 15 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Watts Loss
2 to 3W
Non-Overlap Time
1.5 ms
Electrical Durability
1.65 Mcycles (25 A, AC-3, Less than 440 V); 1.4 Mcycles (40 A, AC-1, Less than 440 V); 1.65 Mcycles (25 A, AC-3e, Less than 440 V)
Switching Current
5 mA (Signalling Circuit)
Operating Time
12 to 22 ms (Closing), 4 to 19 ms (Opening)
Includes Protective Cover
Yes
Switching Voltage
17 V (Signalling Circuit)
Hold VA
7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Net Weight
0.37 kg
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Rated Breaking Capacity
450 A @ 440V
Rated Making Capacity
140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 450 A @ 440V (Power Circuit)
Rated Short-Time Withstand Current
240 A (at 40°C for 10 s Power Circuit), 380 A (at 40°C for 1 s Power Circuit), 50 A (at 40°C for 10 min Power Circuit), 120 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Impedance
2 mOhm
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Environmental Attributes
Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Overvoltage Category
CAT III
Mounting Style
DIN Rail, Plate
Electrical Operating Durability
1,400,000, 1,650,000
Frequency
50/60 Hz
NEMA Enclosure Rating
No Enclosure
Full Load Current - Inductive
25 A
Phase
Three
Includes Auxiliary Contacts
Yes
Horsepower @ Three Phase - 240V AC
7 1/2 hp
Resistance Properties
Fire Resistant, Insulation Resistant
Mechanical Operating Durability
15,000,000
Contactor Style
IEC
Horsepower @ Three Phase - 480V AC
15 hp
Horsepower @ Three Phase - 208V AC
7 1/2 hp
Maximum Voltage Rating
690V AC
Number of Normally Open Main Contacts
3
Horsepower @ Single Phase - 240V AC
3 hp
Maximum Operating Temperature
140 Degrees F
Horsepower @ Three Phase - 600V AC
20 hp
Full Load Current - Resistive
40 A
Minimum Operating Temperature
-40 Degrees F
Horsepower @ Single Phase - 120V AC
2 hp
Embedded Surge Suppressor
No
Conventional Free Air Thermal Current
10 A (at 140°F (60°C)) for signalling circuit; 40 A (at 140°F (60°C)) for power circuit
Protective Treatment
THIEC 60068-2-30
Pollution Degree
3
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Heat Dissipation
2 to 3 W at 50/60 Hz
Control Circuit Voltage
240 V AC 50/60 Hz
Protective Cover
With
Contactor Application
Motor control; Resistive load
Control Circuit Type
AC 50/60 Hz
Auxiliary Contacts Type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
Pole Contact Composition
3 NO
Maximum Operating Rate
3600 cyc/h 140°F (60°C)
Utilisation Category
AC-3; AC-1; AC-3e
Climatic Withstand
IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat
Rated Operational Voltage
Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
Power Dissipation Per Pole
3.2 W AC-1; 1.25 W AC-3; 1.25 W AC-3e
Fire Resistance
1562°F (850°C) IEC 60695-2-1
Contact Compatibility
M2
Rated Operational Current
25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 40 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Mechanical Robustness
Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor closed 15 Gn for 11 ms); Shocks contactor open 8 Gn for 11 ms)
Compatibility Code
LC1D
Inrush Power in VA
70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Operating Altitude
0 to 9842.52 ft (0 to 3000 m)
Ambient Air Temperature For Operation
-40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating

Description

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 240V AC, Number of Poles 3, Full Load Current - Inductive 25 A, Full Load Current - Resistive 40 A, Reversing Capability Non-Reversing, Overall Height 3.35 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC

Ratings & reviews

3 reasons you can count on us

  • Supplies for every job.

    Supplies for every job.

    10 million items and the exact one you need.

  • When you need it fast, count on Zoro!

    When you need it fast, count on Zoro!

    2 million products ship in 1 day.

  • Stretch your budget further.

    Stretch your budget further.

    Everyday low prices on the brands you love.