- Item
- IEC Magnetic Contactor
- Auxiliary Contact Form
- 1NC/1NO
- Coil Voltage
- 24V AC
- Number of Poles
- 3
- Full Load Amps-Inductive
- 12 A
- Full Load Amps-Resistive
- 25 A
- Reversing Capability
- Reversing
- Terminal Connection Type
- Screw Clamp
- Number of Auxillary Contacts
- 2
- Standards
- CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, UL 508
- Series
- TeSys
- HP @ 3 Phase - 575V
- 10 hp
- Non-Overlap Time
- 1.5 ms
- Fuse Amps
- 10 A (Signalling Circuit), 40 A (Type 1 Power Circuit), 25 A (Type 2 Power Circuit)
- Switching Current
- 5 mA (Signalling Circuit)
- Environmental Attributes
- Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
- Max. Operating Watts
- 3 kW (at 220 to 230V AC 50 Hz), 5.5 kW (at 380 to 400V AC 50 Hz), 5.5 kW (at 415 to 440V AC 50 Hz), 7.5 kW (at 500V AC 50 Hz), 7.5 kW (at 660 to 690V AC 50 Hz)
- Shock Resistance
- 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
- Rated Making Capacity
- 250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
- Fire Rating
- UL 94 V1
- Vibration Resistance
- 4 G (Contactor Closed), 2 G (Contactor Open)
- Switching Voltage
- 17 V (Signalling Circuit)
- Control Circuit Voltage Limits
- Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
- Rated Breaking Capacity
- 250 A @ 440V
- Inrush VA
- 70 VA
- Insulation Resistance Range
- Greater Than 10 MOhms (Signalling Circuit)
- Hold VA
- 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
- Watts Loss
- 2 to 3W
- Signalling Circuit Frequency
- 25 to 400 Hz
- Features
- Without Built-In Suppressor Module; Preassembled with Reversing Power Busbar
- Mechanical Durability
- 15 Mcycles
- Application
- Motor Control, Resistive Load
- Rated Insulation Volts
- 600/690V
- Includes Protective Cover
- Yes
- Overvoltage Category
- CAT III
- Net Weight
- 0.697 kg
- Electrical Durability
- 2 Mcycles (12 A, AC-3, Less than 440 V); 0.8 Mcycles (25 A, AC-1, Less than 440 V)
- Rated Short-Time Withstand Current
- 30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
- Impedance
- 2.5 mOhm
- IP Rating
- IP20
- Impulse Withstand Voltage
- 6 kV
- Operating Speed
- 3600 cycles per hr
- Operating Time
- 12 to 22 ms (Closing), 4 to 19 ms (Opening)
- Tightening Torque
- 1.7 Nm (Control Circuit), 1.7 to 2.5 Nm (Power Circuit)
- Horsepower @ Three Phase - 240V AC
- 3 hp
- Horsepower @ Single Phase - 240V AC
- 2 hp
- Full Load Current - Resistive
- 25 A
- Full Load Current - Inductive
- 12 A
- Horsepower @ Three Phase - 480V AC
- 7 1/2 hp
- Horsepower @ Three Phase - 208V AC
- 3 hp
- Horsepower @ Three Phase - 600V AC
- 10 hp
- Contactor Style
- IEC
- Frequency
- 50/60 Hz
- Electrical Operating Durability
- 2,000,000
- Maximum Operating Temperature
- 60 Degrees F
- Includes Auxiliary Contacts
- Yes
- Maximum Voltage Rating
- 690V AC
- Mechanical Operating Durability
- 15,000,000
- Minimum Operating Temperature
- -40 Degrees F
- Mounting Style
- Plate, DIN Rail
- Response Time
- 12 to 22 msec (Closing), 4 to 19 msec (Opening)
- Number of Normally Open Main Contacts
- 3
- Resistance Properties
- Fire Resistant, Insulation Resistant
- Conventional Free Air Thermal Current
- 10 A (at 60°C Signalling Circuit), 25 A (at 60°C Power Circuit)
- Phase
- Three
- Embedded Surge Suppressor
- No
- Number of Normally Closed Main Contacts
- 1