IEC Magnetic Contactor, 1NC/1NO, 24V DC, 3 P, Non-Reversing, Screw Clamp

  • Mfr # LC1D65ABD

  • Zoro # G2412487


product price:  $463.99
/ea
Free Shipping & Returns

Key Features

Auxiliary Contact Form
1NC/1NO
Coil Voltage
24V DC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
See all product information
Get a 10% off coupon
Free 30-day returns
Return Policy
Get 30 days to pay with Net 30
Apply Now
Unlock tax-exempt savings
Add Tax Exemption

Specifications

Product Information

MFR #
LC1D65ABD
Zoro #
G2412487
UPC #
785901565468
Country of Origin
France

Dimensions

Working Height
Up to 9842.52 ft
Overall Depth
4.72 in
Overall Width
2.17 in
Overall Height
4.8 in

Details

Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Coil Voltage
24V DC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
CCC, CSA, CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, UL Listed
HP @ 3 Phase - 575V
50 hp
Reversing
No
HP @ 1 Phase - 230V
10
Enclosure NEMA Rating
No Enclosure
Includes
Everlink Power Connections
Series
TeSys Deca
Features
Built-In Bi-Directional Peak Limiting Diode Suppressor
Control Circuit Voltage Limits
Drop-Out DC: 0.1 to 0.3 Uc (at -40 to 70°C); Operational DC: 0.75 to 1.25 Uc (at -40 to 60°C), 1 to 1.25 Uc (at 60 to 70°C)
Application
Motor Control, Resistive Load
Operating Time
42.5 to 57.5 ms (Closing), 16 to 24 ms (Opening)
Impulse Withstand Voltage
6 kV
Rated Making Capacity
140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1000 A @ 440V (Power Circuit)
Net Weight
0.935 kg
Includes Protective Cover
Yes
Non-Overlap Time
1.5 ms
Environmental Attributes
Mercury Free, PVC Free, Pollution Degree 3
Overvoltage Category
CAT III
Signalling Circuit Frequency
25 to 400 Hz
Electrical Durability
0.5 Mcycles (80 A, AC-1, Less than 440 V); 1.45 Mcycles (65 A, AC-3, Less than 440 V); 1.45 Mcycles (65 A, AC-3e, Less than 440 V)
Fuse Amps
10 A (Signalling Circuit), 125 A (Type 1 Power Circuit), 125 A (Type 2 Power Circuit)
Operating Speed
3600 cycles per hr
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Rated Short-Time Withstand Current
520 A (at 40°C for 10 s Power Circuit), 900 A (at 40°C for 1 s Power Circuit), 110 A (at 40°C for 10 min Power Circuit), 260 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Rated Breaking Capacity
1000 A @ 440V
Rated Insulation Volts
600/690V
IP Rating
IP20
Tightening Torque
1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit)
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Switching Current
5 mA (Signalling Circuit)
Switching Voltage
17 V (Signalling Circuit)
Fire Rating
UL 94 V1
Shock Resistance
10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Mechanical Durability
10 Mcycles
Impedance
1.5 mOhm
Max. Operating Watts
11 kW (at 400V AC 50/60 Hz AC-4), 18.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 30 kW (at 380 to 400V AC 50/60 Hz AC-3), 37 kW (at 500V AC 50/60 Hz AC-3), 37 kW (at 660 to 690V AC 50/60 Hz AC-3), 18.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 30 kW (at 380 to 400V AC 50/60 Hz AC-3e), 37 kW (at 500V AC 50/60 Hz AC-3e), 37 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Number of Normally Open Main Contacts
3
Horsepower @ Single Phase - 120V AC
5 hp
Resistance Properties
Fire Resistant, Insulation Resistant
Full Load Current - Inductive
65 A
Includes Auxiliary Contacts
Yes
Mounting Style
DIN Rail, Plate
Horsepower @ Three Phase - 600V AC
50 hp
Horsepower @ Three Phase - 480V AC
40 hp
NEMA Enclosure Rating
No Enclosure
Horsepower @ Three Phase - 240V AC
20 hp
Horsepower @ Three Phase - 208V AC
20 hp
Electrical Operating Durability
1,450,000, 500,000
Maximum Operating Temperature
140 Degrees F
Frequency
50/60 Hz
Contactor Style
IEC
Maximum Voltage Rating
690V AC
Mechanical Operating Durability
10,000,000
Minimum Operating Temperature
-40 Degrees F
Full Load Current - Resistive
80 A
Phase
Three
Horsepower @ Single Phase - 240V AC
10 hp
Embedded Surge Suppressor
Yes
Climatic Withstand
IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat
Maximum Operating Rate
3600 cyc/h 140°F (60°C)
Protective Treatment
THIEC 60068-2-30
Hold-In Power Consumption in W
7.4 W 68°F (20°C)
Pollution Degree
3
Time Constant
34 ms
Conventional Free Air Thermal Current
10 A (at 140°F (60°C)) for signalling circuit; 80 A (at 140°F (60°C)) for power circuit
Operating Altitude
0 to 9842.52 ft (0 to 3000 m)
Power Dissipation Per Pole
9.6 W AC-1; 6.3 W AC-3; 6.3 W AC-3e
Auxiliary Contacts Type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
Contactor Application
Motor control; Resistive load
Protective Cover
With
Rated Operational Current
80 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 65 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 65 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Contact Compatibility
M4
Mechanical Robustness
Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor closed 15 Gn for 11 ms); Shocks contactor open 10 Gn for 11 ms)
Utilisation Category
AC-4; AC-1; AC-3; AC-3e
Fire Resistance
1562°F (850°C) IEC 60695-2-1
Pole Contact Composition
3 NO
Control Circuit Type
DC standard
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Compatibility Code
LC1D
Rated Operational Voltage
Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
Inrush Power in W
19 W 68°F (20°C)
Ambient Air Temperature For Operation
-40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating

Description

The SCHNEIDER ELECTRIC - IEC Magnetic Contactor is a non-reversing, three-pole contactor designed for motor control and resistive load applications. It operates with a coil voltage of 24V DC and has an auxiliary contact configuration of 1NO/1NC. The contactor features built-in bidirectional peak limiting diode suppressor technology and mechanically linked auxiliary contacts. With a compatibility code of LC1D, it offers screw clamp terminals for secure electrical connections.

Key Features:

  • Non-Reversing action suitable for specific circuit configurations.
  • Auxiliary Contact Form: 1NC/1NO provides versatility in circuit design.
  • Average Impedance: 1.5 mOhm ensures efficient operation.
  • Coil Technology: Built-in bidirectional peak limiting diode suppressor aids in reducing voltage spikes.
  • Connections - Terminals: Screw clamp terminals provide secure connections for both power and control circuits.
  • Electrical Durability rated at up to 0.5 Mcycles (80 A, AC-1), designed for operation under specified conditions
  • -Includes Protective Cover intended for use during usage or installation process
  • -Mounting Style supports both DIN Rail and Plate mounting offering flexibility during installation
  • -Maximum Operating Rate of 3600 cyc/h is achievable within optimal temperature conditions
  • -Rated Insulation Voltage allows operation within specified voltage limits
  • Ratings & Reviews

    3 Reasons You Can Count On Us

    • Supplies for every job.

      Supplies for every job.

      10 million items and the exact one you need.

    • When you need it fast, count on Zoro!

      When you need it fast, count on Zoro!

      2 million products ship in 1 day.

    • Stretch your budget further.

      Stretch your budget further.

      Everyday low prices on the brands you love.