- Item
- IEC Magnetic Contactor
- Auxiliary Contact Form
- 1NO
- Coil Voltage
- 110V AC
- Number of Poles
- 3
- Full Load Amps-Inductive
- 9 A
- Full Load Amps-Resistive
- 20 A
- Reversing Capability
- Reversing
- Terminal Connection Type
- Screw Clamp
- Number of Auxillary Contacts
- 1
- Standards
- EN/IEC 60947-4-1, GB/T 14048.4, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, CB Scheme, CCC, UL, CSA, EAC, CE, UKCA, TC IEC 60068, TC DIN 50016
- Series
- LC2K
- Control Circuit Voltage Limits
- Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C)
- Net Weight
- 0.39 kg
- Electrical Durability
- 0.18 Mcycles (20 A, AC-1, Less than 440 V); 1.3 Mcycles (9 A, AC-3, Less than 440 V); 1.3 Mcycles (9 A, AC-3e, Less than 440 V)
- Switching Current
- 5 mA (Signalling Circuit)
- Impulse Withstand Voltage
- 8 kV
- Rated Short-Time Withstand Current
90 A (at 50°C for 1 s Power Circuit), 85 A (at 50°C for 5 s Power Circuit), 80 A (at 50°C for 10 s Power Circuit), 60 A (at 50°C for 30 s Power Circuit), 45 A (at 50°C for 1 min Power Circuit), 40 A (at 50°C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 20 A (at 50°C for 15 min Power Circuit)
- Fuse Amps
- 25 A (Power Circuit), 10 A (Signalling Circuit)
- Application
- Motor Control, Resistive Load
- Fire Rating
- UL 94 V1, NF F 16-101, NF F 16-102
- Environmental Attributes
- Mercury Free, Toxic Heavy Metal Free
- Impedance
- 3 mOhm
- Watts Loss
- 1.3W
- Hold VA
- 4.5 VA
- Rated Making Capacity
- 110 A
- Rated Insulation Volts
- 600/690V
- Features
- Preassembled with Reversing Power Busbar
- Max. Operating Watts
- 2.2 kW (at 220 to 230V AC 50/60 Hz), 4 kW (at 380 to 415VAC 50/60 Hz), 4 kW (at 440V AC 50/60 Hz), 4 kW (at 480V AC 50/60 Hz), 4 kW (at 500 to 600V AC 50/60 Hz), 4 kW (at 660 to 690V AC 50/60 Hz)
- Insulation Resistance Range
- Greater Than 10 MOhms (Signalling Circuit)
- Operating Speed
- 3600 cycles per hr
- Switching Voltage
- 17 V (Signalling Circuit)
- Operating Time
- 10 to 20 ms (Coil Energisation and NO Closing), 10 to 20 ms (Coil De-Energisation and NO Opening)
- Shock Resistance
- 10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open)
- Mechanical Durability
- 5 Mcycles
- Inrush VA
- 30 VA
- Signalling Circuit Frequency
- Less Than 400 Hz
- Tightening Torque
- 0.8 to 1.3 Nm
- Rated Breaking Capacity
- 110 A @ 415V, 440V, 220 to 230V, 380 to 400 V; 80 A @ 500V; 70 A @ 660 to 690V
- Overvoltage Category
- CAT III
- Vibration Resistance
- 4 G (Contactor Closed), 2 G (Contactor Open)
- IP Rating
- IP20
- Mechanical Robustness
Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27; Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6; Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6
- Non Overlap Distance
- 0.02 in (0.5 mm)
- Control Circuit Type
- AC 50/60 Hz
- Product Name
- TeSys K
- Protective Treatment
- TC IEC 60068; TC DIN 50016
- Utilisation Category
- AC-3; AC-3e; AC-4; AC-1
- Contactor Application
- Resistive load; Motor control
- Auxiliary Contacts Type
- Instantaneous 1 NO
- Conventional Free Air Thermal Current
- 20 A (at 140°F (60°C)) for power circuit; 10 A (at 122°F (50°C)) for signalling circuit
- Interlocking Type
- Mechanical
- Ambient Air Temperature For Operation
- -13 to 122°F (-25 to 50°C)
- Rated Operational Voltage
- Power circuit 690 V AC 50/60 Hz; Signalling circuit Less than or Equal to 690 V AC 50/60 Hz
- Device Application
- Control
- Operating Altitude
- 6561.68 ft (2000 m) without derating
- Safety Reliability Level
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Ambient Air Temperature For Storage
- -58 to 176°F (-50 to 80°C)
- Maximum Operating Rate
- 3600 cyc/h
- Inrush Power in VA
- 30 VA (at 68°F (20°C))
- Rated Operational Current
- 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit; 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit
- Heat Dissipation
- 1.3 W
- Control Circuit Voltage
- 110 V AC 50/60 Hz
- Full Load Current - Inductive
- 9 A
- Full Load Current - Resistive
- 20 A
- Maximum Voltage Rating
- 690V AC
- Mounting Style
- Plate, Rail
- Pole Contact Composition
- 3 NO