IEC Magnetic Contactor, 1NO, 120V AC, 3 P, Non-Reversing, Screw Clamp

  • Mfr # DPE18G7

  • Zoro # G503481082


product price:  $42.55
/ea

Key Features

Auxiliary Contact Form
1NO
Coil Voltage
120V AC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
See all product information
Get a 10% off coupon
Free 30-day returns
Return Policy
Get 30 days to pay with Net 30
Apply Now
Unlock tax-exempt savings
Add Tax Exemption

Specifications

Product Information

MFR #
DPE18G7
Zoro #
G503481082
UPC #
-
Country of Origin
Indonesia

Dimensions

Overall Width
1.77 in
Overall Height
3.03 in
Working Height
Up to 6561.68 ft
Overall Depth
3.39 in

Details

Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NO
Coil Voltage
120V AC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
1
Standards
CSA, CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL Listed, UL 60947-4-1
Frame / Series / Class / Code
TeSys
Reversing
No
HP @ 3 Phase - 575V
10 hp
Enclosure NEMA Rating
3R; 4
Special Features
Overvoltage Category III; Minimum Switching Voltage 17 V Signalling Circuit; Insulation Resistance 10 MOhm Signalling Circuit
Features
Without Built-In Suppressor Module
Application
Motor Control, Resistive Load
Switching Current
5 mA (Signalling Circuit)
Operating Time
12 to 22 ms (Closing), 4 to 19 ms (Opening)
Rated Making Capacity
250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Series
TeSys Easy
Fuse Amps
10 A (Signalling Circuit), 40 A (Type 1 Power Circuit), 25 A (Type 2 Power Circuit)
Electrical Durability
1 Mcycles (18 A, AC-3, Less than 440 V); 0.6 Mcycles (25 A, AC-1, Less than 440 V)
Impulse Withstand Voltage
6 kV
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Max. Operating Watts
4 kW (at 220 to 230V AC 50/60 Hz), 7.5 kW (at 380 to 400V AC 50/60 Hz), 9 kW (at 415V AC 50/60 Hz), 9 kW (at 440V AC 50/60 Hz), 10 kW (at 500V AC 50/60 Hz), 10 kW (at 660 to 690V AC 50/60 Hz)
Net Weight
0.325 kg
Watts Loss
2 to 3W
Mechanical Durability
10 Mcycles
Switching Voltage
17 V (Signalling Circuit)
Non-Overlap Time
1.5 ms
Impedance
2.5 mOhm
Environmental Attributes
Mercury Free, Toxic Heavy Metal Free, Pollution Degree 3
Tightening Torque
1.7 Nm
Inrush VA
70 VA
Operating Speed
3600 cycles per hr
Control Circuit Voltage Limits
Drop-Out: 0.3 to 0.6 Uc (at 70°C 50/60 Hz); Operational: 0.8 to 1.1 Uc (at 60°C 50 Hz 0.85 to 1.1 Uc (at 60°C 60 Hz), 1 to 1.1 Uc (at 70°C 50/60 Hz)
IP Rating
IP20
Overvoltage Category
CAT III
Hold VA
7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Rated Insulation Volts
600/690V
Signalling Circuit Frequency
25 to 400 Hz
Shock Resistance
15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Rated Breaking Capacity
250 A @ 440V
Electrical Operating Durability
1,000,000, 600,000
Horsepower @ Three Phase - 240V AC
3 hp
Full Load Current - Resistive
18 A
Maximum Operating Temperature
140 Degrees F
Number of Normally Open Main Contacts
3
Includes Auxiliary Contacts
Yes
Frequency
50/60 Hz
Maximum Voltage Rating
690V AC
NEMA Enclosure Rating
No Enclosure
Minimum Operating Temperature
-40 Degrees F
Horsepower @ Three Phase - 600V AC
10 hp
Mechanical Operating Durability
10,000,000
Horsepower @ Single Phase - 240V AC
2 hp
Full Load Current - Inductive
18 A
Mounting Style
DIN Rail, Plate
Horsepower @ Three Phase - 208V AC
3 hp
Contactor Style
IEC
Resistance Properties
Fire Resistant, Insulation Resistant
Horsepower @ Three Phase - 480V AC
7 1/2 hp
Embedded Surge Suppressor
No
Horsepower @ Single Phase - 120V AC
1/2 hp
Conventional Free Air Thermal Current
10 A (at 60°C Signalling Circuit), 25 A (at 60°C Power Circuit)

Description

The Schneider Electric IEC Magnetic Contactor is a 3-pole, non-reversing switching device with a 120 V AC coil and 1 normally open auxiliary contact (1NO). It uses screw clamp terminals and is rated for use with motor control and resistive loads within specified parameters. The device is part of the TeSys family and is rated for operation at 50/60 Hz within the specified voltage range up to 690 V AC. Main contacts total 3 NO, complemented by 1 NO auxiliary contact; does not include reversing functionality.

Coil voltage: 120 V AC

  • Poles/Main Contacts: 3 poles; 3 NO main contacts; Auxiliary contact: 1 NO
  • Reversing: Non-Reversing
  • Terminals: Screw Clamp
  • Enclosure: IP20; Enclosure ratings are as specified; no additional enclosure features implied
  • Series: TeSys
  • Frequency: 50/60 Hz
  • Maximum/Insulation Voltage: 690 V AC; Rated Insulation: 600/690 V
  • Full Load Amps: Inductive 18 A; Resistive 18 A
  • Rated Making Capacity: Rated making capacity based on standard testing conditions
  • Rated Breaking Capacity: Rated breaking capacity under specified test conditions
  • Embedded Surge Suppressor: does not include an embedded surge suppressor
  • Dimensions/Weight: Depth 3.39 in; Height 3.03 in; Width 1.77 in; Net weight 0.325 kg
  • Mounting: compatible with mounting on DIN rail or plate according to installation instructions
  • Mechanical/Electrical Durability: tested durability within standardized cycles under controlled conditions
  • Operating Time/Non-Overlap: operating times are based on typical performance specifications under test conditions
  • Hold VA: power consumption during holding is within the rated values at specified frequencies and temperatures
  • Impulse/Signal: signal characteristics are as per manufacturer specifications for signalling circuits only
  • Fuses: fuse ratings are provided as per product design specifications, subject to proper application guidelines
  • Standards: CSA, CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL Listed, UL 60947-4-1
  • Special Features: Overvoltage Category III; Minimum Switching Voltage 17 V Signalling Circuit; Insulation Resistance 10 MΩ Signalling Circuit
  • Environmental: Mercury Free; Toxic Heavy Metal Free; Pollution Degree 3
  • Series/Model Details: TeSys
  • Additional ratings: Max. Temperature 850°C (max.), Maximum Operating Temperature 140°F; Rated Voltage 690V AC, 300V DC; Resistance/Impedance 2.5 mΩ
  • Reversing/Signalling: Non-Reversing; Includes Auxiliary Contacts: Yes
  • Ratings & Reviews

    3 Reasons You Can Count On Us

    • Supplies for every job.

      Supplies for every job.

      10 million items and the exact one you need.

    • When you need it fast, count on Zoro!

      When you need it fast, count on Zoro!

      2 million products ship in 1 day.

    • Stretch your budget further.

      Stretch your budget further.

      Everyday low prices on the brands you love.