- Item
- IEC Magnetic Contactor
- Auxiliary Contact Form
- 1NO
- Coil Voltage
- 220V AC
- Number of Poles
- 3
- Full Load Amps-Inductive
- 6 A
- Terminal Connection Type
- Screw Clamp
- Number of Auxillary Contacts
- 1
- Standards
- EN/IEC 60947-4-1, GB/T 14048.4, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, CB Scheme, CCC, UL, CSA, EAC, CE, UKCA, TC IEC 60068, TC DIN 50016
- Series
- LC1K, TeSys
- Vibration Resistance
- 4 G (Contactor Closed), 2 G (Contactor Open)
- Shock Resistance
- 10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open)
- Switching Voltage
- 17 V (Signalling Circuit)
- Net Weight
- 0.18 kg
- Max. Operating Watts
1.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 2.2 kW (at 380 to 415V AC 50/60 Hz AC-3), 3 kW (at 440V AC 50/60 Hz AC-3), 3 kW (at 480V AC 50/60 Hz AC-3), 3 kW (at 500 to 600V AC 50/60 Hz AC-3), 3 kW (at 660 to 690V AC 50/60 Hz AC-3), 1.5 kW (at 400V AC 50/60 Hz AC-4), 1.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 2.2 kW(at 380 to 415V AC 50/60 Hz AC-3e), 3 kW (at 440V AC 50/60 Hz AC-3e), 3 kW (at 480V AC 50/60 Hz AC-3e), 3 kW (at 500 to 600V AC 50/60 Hz AC-3e), 3 kW (at 660 to 690V AC 50/60 Hz AC-3e)
- Application
- Motor Control
- Inrush VA
- 30 VA
- Tightening Torque
- 0.8 to 1.3 Nm
- Hold VA
- 4.5 VA
- Fire Rating
- UL 94 V1, NF F 16-101, NF F 16-102
- Electrical Durability
- 1.3 Mcycles (6 A, AC-3, Less than 440 V); 1.3 Mcycles (6 A, AC-3e, Less than 440 V)
- Operating Speed
- 3600 cycles per hr
- Rated Making Capacity
- 110 A
- Signalling Circuit Frequency
- Less Than 400 Hz
- Rated Insulation Volts
- 600/690V
- Impedance
- 3 mOhm
- Watts Loss
- 1.3W
- Switching Current
- 5 mA (Signalling Circuit)
- Impulse Withstand Voltage
- 8 kV
- IP Rating
- IP2X
- Environmental Attributes
- Mercury Free, Toxic Heavy Metal Free
- Insulation Resistance Range
- Greater Than 10 MOhms (Signalling Circuit)
- Mechanical Durability
- 10 Mcycles
- Fuse Amps
- 25 A (Power Circuit), 10 A (Signalling Circuit)
- Rated Breaking Capacity
- 110 A @ 415V, 440V, 220 to 230V, 380 to 400 V; 80 A @ 500V; 70 A @ 660 to 690V
- Overvoltage Category
- CAT III
- Rated Short-Time Withstand Current
90 A (at 50°C for 1 s Power Circuit), 85 A (at 50°C for 5 s Power Circuit), 80 A (at 50°C for 10 s Power Circuit), 60 A (at 50°C for 30 s Power Circuit), 45 A (at 50°C for 1 min Power Circuit), 40 A (at 50°C for 3 min Power Circuit), 20 A (at 50°C for 15 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit)
- Control Circuit Voltage Limits
- Operational: 0.85 to 1.1 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C)
- Operating Time
- 10 to 20 ms (Coil De-Energisation and NO Opening), 10 to 20 ms (Coil Energisation and NO Closing)
- [Ui] Rated Insulation Voltage
- power circuit 600 V UL 508, power circuit 690 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-5-1, signalling circuit 600 V UL 508, power circuit 600 V CSA C22.2 No 14, signalling circuit 600 V CSA C22.2 No 14
- Auxiliary Contacts Type
- instantaneous 1 NO
- Device Application
- control
- Heat Dissipation
- 1.3-1.3 W
- Maximum Operating Rate
- 3600 cyc/h
- Protective Treatment
- TC IEC 60068, TC DIN 50016
- Mechanical Robustness
shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27, shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27, shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27, shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27, shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27, shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27, vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6, vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
- Non Overlap Distance
- 0.5 mm
- Ambient Air Temperature For Storage
- -50-80°C
- Operating Altitude
- 6561.68 ft (2000 m) without derating
- [Icw] Rated Short-Time Withstand Current
90 A 50°C - 1 s for power circuit, 85 A 50°C - 5 s for power circuit, 80 A 50°C - 10 s for power circuit, 60 A 50°C - 30 s for power circuit, 45 A 50°C - 1 min for power circuit, 40 A 50°C - 3 min for power circuit, 20 A 50°C - >= 15 min for power circuit, 80 A - 1 s for signalling circuit, 90 A - 500 ms for signalling circuit, 110 A - 100 ms for signalling circuit
- Control Circuit Type
- AC 50/60 Hz
- Utilisation Category
- AC-3, AC-3e, AC-4
- Pole Contact Composition
- 3 NO
- Full Load Current - Inductive
- 8.3 A
- Mounting Style
- Plate, Rail
- Conventional Free Air Thermal Current
- 20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit)
- Rated Operational Voltage
- power circuit <= 690 V AC <= 400 Hz, signalling circuit <= 690 V AC <= 400 Hz
- Control Circuit Voltage
- 220...230 V AC 50/60 Hz
- Inrush Power in VA
- 30-30 VA (at 20°C)
- Maximum Voltage Rating
- 690V AC
- Rated Operational Current
- 6 A (at <60°C) at <= 440 V AC AC-3 for power circuit, 6 A (at <60°C) at <= 440 V AC AC-3e for power circuit