IEC Magnetic Contactor, 1NC/1NO, 200V AC, 3 P, Non-Reversing, Screw Clamp

  • Mfr # LC1D65AL7

  • Zoro # G1554822


product price:  $362.99
/ea
Free Shipping & Returns

Key Features

Auxiliary Contact Form
1NC/1NO
Coil Voltage
200V AC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
See all product information
Get a 10% off coupon
Free 30-day returns
Return Policy
Get 30 days to pay with Net 30
Apply Now
Real support from real people
Contact our U.S. based team

Specifications

Product Information

MFR #
LC1D65AL7
Zoro #
G1554822
UPC #
785901565642
Country of Origin
France

Dimensions

Working Height
Up to 9842.52 ft
Overall Height
4.8 in
Overall Width
2.17 in
Overall Depth
4.72 in

Details

Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Coil Voltage
200V AC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
CCC, CSA, CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, UL Listed
HP @ 1 Phase - 230V
10
HP @ 3 Phase - 575V
50 hp
Enclosure NEMA Rating
No Enclosure
Reversing
No
Series
TeSys Deca
Includes
Everlink Power Connections
Rated Short-Time Withstand Current
520 A (at 40°C for 10 s Power Circuit), 900 A (at 40°C for 1 s Power Circuit), 110 A (at 40°C for 10 min Power Circuit), 260 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Electrical Durability
1.4 Mcycles (80 A, AC-1, Less than 440 V); 1.45 Mcycles (65 A, AC-3, Less than 440 V); 1.45 Mcycles (65 A, AC-3e, Less than 440 V)
Mechanical Durability
6 Mcycles
Switching Current
5 mA (Signalling Circuit)
Impedance
1.5 mOhm
Fuse Amps
10 A (Signalling Circuit), 125 A (Type 1 Power Circuit), 125 A (Type 2 Power Circuit)
Includes Protective Cover
Yes
Shock Resistance
10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Inrush VA
140 VA (at 60 Hz 20°C), 160 VA (at 50 Hz 20°C)
Control Circuit Voltage Limits
Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Signalling Circuit Frequency
25 to 400 Hz
Features
Without Built-In Suppressor Module
Operating Speed
3600 cycles per hr
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Net Weight
0.86 kg
IP Rating
IP20
Rated Insulation Volts
600/690V
Impulse Withstand Voltage
6 kV
Tightening Torque
1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit)
Operating Time
4 to 19 ms (Opening), 12 to 26 ms (Closing)
Rated Breaking Capacity
1000 A @ 440V
Watts Loss
4 to 5W
Environmental Attributes
Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Switching Voltage
17 V (Signalling Circuit)
Overvoltage Category
CAT III
Application
Motor Control, Resistive Load
Non-Overlap Time
1.5 ms
Rated Making Capacity
140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1000 A @ 440V (Power Circuit)
Max. Operating Watts
11 kW (at 400V AC 50/60 Hz AC-4), 18.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 30 kW (at 380 to 400V AC 50/60 Hz AC-3), 37 kW (at 500V AC 50/60 Hz AC-3), 37 kW (at 660 to 690V AC 50/60 Hz AC-3), 18.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 30 kW (at 380 to 400V AC 50/60 Hz AC-3e), 37 kW (at 500V AC 50/60 Hz AC-3e), 37 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Fire Rating
UL 94 V1
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Hold VA
13 VA (at 60 Hz 20°C), 15 VA (at 50 Hz 20°C)
Full Load Current - Resistive
80 A
Frequency
50/60 Hz
Contactor Style
IEC
Phase
Three
Resistance Properties
Fire Resistant, Insulation Resistant
Maximum Voltage Rating
690V AC
Horsepower @ Three Phase - 600V AC
50 hp
Number of Normally Open Main Contacts
3
Includes Auxiliary Contacts
Yes
Horsepower @ Three Phase - 208V AC
20 hp
Horsepower @ Three Phase - 240V AC
20 hp
Embedded Surge Suppressor
No
Horsepower @ Single Phase - 120V AC
5 hp
Electrical Operating Durability
1,400,000, 1,450,000
Horsepower @ Single Phase - 240V AC
10 hp
Maximum Operating Temperature
140 Degrees F
NEMA Enclosure Rating
No Enclosure
Mechanical Operating Durability
6,000,000
Minimum Operating Temperature
-40 Degrees F
Mounting Style
DIN Rail, Plate
Horsepower @ Three Phase - 480V AC
40 hp
Full Load Current - Inductive
65 A
Operating Altitude
0 to 9842.52 ft (0 to 3000 m)
Auxiliary Contacts Type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
Protective Treatment
THIEC 60068-2-30
Pole Contact Composition
3 NO
Pollution Degree
3
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Contact Compatibility
M2
Compatibility Code
LC1D
Climatic Withstand
IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat
Fire Resistance
1562°F (850°C) IEC 60695-2-1
Control Circuit Voltage
200 V AC 50/60 Hz
Heat Dissipation
4 to 5 W at 50/60 Hz
Contactor Application
Resistive load; Motor control
Control Circuit Type
AC 50/60 Hz
Power Dissipation Per Pole
9.6 W AC-1; 6.3 W AC-3; 6.3 W AC-3e
Mechanical Robustness
Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor closed 15 Gn for 11 ms); Shocks contactor open 10 Gn for 11 ms)
Utilisation Category
AC-4; AC-1; AC-3; AC-3e
Maximum Operating Rate
3600 cyc/h 140°F (60°C)
Conventional Free Air Thermal Current
10 A (at 140°F (60°C)) for signalling circuit; 80 A (at 140°F (60°C)) for power circuit
Protective Cover
With
Rated Operational Current
80 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 65 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 65 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Rated Operational Voltage
Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
Inrush Power in VA
140 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 160 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Ambient Air Temperature For Operation
-40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating

Description

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 200V AC, Number of Poles 3, Full Load Current - Inductive 65 A, Full Load Current - Resistive 80 A, Reversing Capability Non-Reversing, Overall Height 4.8 in, Overall Width 2.17 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC

Ratings & Reviews

3 Reasons You Can Count On Us

  • Supplies for every job.

    Supplies for every job.

    10 million items and the exact one you need.

  • When you need it fast, count on Zoro!

    When you need it fast, count on Zoro!

    2 million products ship in 1 day.

  • Stretch your budget further.

    Stretch your budget further.

    Everyday low prices on the brands you love.