Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
Frame / Series / Class / Code
TeSys
Enclosure NEMA Rating
No Enclosure
HP @ 3 Phase - 575V
125 hp
Rated Breaking Capacity
1400 A @ 440V
Fuse Amps
10 A (Signalling Circuit), 315 A (Type 1 Power Circuit), 250 A (Type 2 Power Circuit)
Signalling Circuit Frequency
25 to 400 Hz
Overvoltage Category
CAT III
Environmental Attributes
Mercury Free, PVC Free, Pollution Degree 3
Shock Resistance
15 G for 11 ms (Contactor Closed), 6 G for 11 ms (Contactor Open)
Tightening Torque
1.2 Nm (Control Circuit), 12 Nm (Power Circuit)
Rated Short-Time Withstand Current
250 A (at 40°C for 10 min Power Circuit), 580 A (at 40°C for 1 min Power Circuit), 1200 A (at 40°C for 10 s Power Circuit), 1400 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Operating Time
20 to 35 ms (Closing), 40 to 75 ms (Opening)
Electrical Durability
0.85 Mcycles (150 A, AC-3, Less than 440 V); 1 Mcycles (200 A, AC-1, Less than 440 V); 0.85 Mcycles (150 A, AC-3e, Less than 440 V)
Mechanical Durability
8 Mcycles
Switching Current
5 mA (Signalling Circuit)
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Features
With Integral Suppression Device
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Rated Insulation Volts
600/1000V (Power Circuit), 600/690V (Signalling Circuit)
Max. Operating Watts
40 kW (at 220 to 230V AC 50/60 Hz AC-3), 75 kW (at 380 to 400V AC 50/60 Hz AC-3), 80 kW 415 to (at 440V AC 50/60 Hz AC-3), 90 kW (at 500V AC 50/60 Hz AC-3), 100 kW (at 660 to 690V AC 50/60 Hz AC-3), 75 kW (at 1000V AC 50/60 Hz AC-3), 22 kW (at 400V AC 50/60 Hz AC-4), 40 kW (at 220 to 230V AC 50/60 Hz AC-3e), 75 kW (at 380 to 400V AC 50/60 Hz AC-3e), 80 kW (at 415 to 440V AC 50/60 Hz AC-3e), 90 kW (at 500V AC 50/60 Hz AC-3e), 100 kW (at 660 to 690V AC 50/60 Hz AC-3e), 75 kW (at 1000V AC 50/60 Hz AC-3e)
Switching Voltage
17 V (Signalling Circuit)
Operating Speed
1200 cycles per hr
Includes Protective Cover
Yes
Impulse Withstand Voltage
8 kV
Application
Motor Control, Resistive Load
Rated Making Capacity
140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1660 A @ 440V (Power Circuit)
Control Circuit Voltage Limits
Operational DC: 0.75 to 1.2 Uc (at -40 to 55°C), 1 to 1.2 Uc (at 55 to 70°C); Drop-Out DC: 0.15 to 0.4 Uc (at -40 to 70°C)
Horsepower @ Single Phase - 240V AC
3 hp
Minimum Operating Temperature
-40 Degrees F
Embedded Surge Suppressor
Yes
Full Load Current - Resistive
200 A
Horsepower @ Three Phase - 600V AC
125 hp
Mounting Style
DIN Rail, Plate
Horsepower @ Three Phase - 240V AC
50 hp
Electrical Operating Durability
1,000,000, 850,000
NEMA Enclosure Rating
No Enclosure
Horsepower @ Three Phase - 480V AC
100 hp
Resistance Properties
Fire Resistant, Insulation Resistant
Full Load Current - Inductive
150 A
Maximum Operating Temperature
140 Degrees F
Includes Auxiliary Contacts
Yes
Horsepower @ Three Phase - 208V AC
40 hp
Maximum Voltage Rating
1000V AC
Number of Normally Open Main Contacts
3
Mechanical Operating Durability
8,000,000
Power Dissipation Per Pole
24 W AC-1; 13.5 W AC-3; 13.5 W AC-3e
Pole Contact Composition
3 NO
Rated Operational Voltage
Power circuit Less than or Equal to 1000 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Maximum Operating Rate
1200 cyc/h 140°F (60°C)
Mechanical Robustness
Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor closed 15 Gn for 11 ms); Shocks contactor open 6 Gn for 11 ms)
Contactor Application
Resistive load; Motor control
Auxiliary Contacts Type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
Utilisation Category
AC-3; AC-4; AC-1; AC-3e
Contact Compatibility
M10
Conventional Free Air Thermal Current
200 A (at 140°F (60°C)) for power circuit
Protective Treatment
THIEC 60068-2-30
Rated Operational Current
200 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 150 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 150 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Climatic Withstand
IACS E10 exposure to damp heat
Operating Altitude
0 to 9842.52 ft (0 to 3000 m)
Hold-In Power Consumption in W
2.4 to 5.1 W 68°F (20°C)
Control Circuit Type
DC standard
Inrush Power in W
270 to 365 W 68°F (20°C)
Fire Resistance
1562°F (850°C) IEC 60695-2-1
Ambient Air Temperature For Operation
-40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating