IEC Miniature Magnetic Contactor, 1NC, 120V AC, 3 P, Reversing, Screw Clamp

  • Mfr # LC2K1201G7

  • Zoro # G1251363


product price:  $226.99
/ea
Free Shipping & Returns

Key Features

Auxiliary Contact Form
1NC
Coil Voltage
120V AC
Number of Poles
3
Reversing Capability
Reversing
Terminal Connection Type
Screw Clamp
See all product information
Get a 10% off coupon
Free 30-day returns
Return Policy
Get 30 days to pay with Net 30
Apply Now
Unlock tax-exempt savings
Add Tax Exemption

Specifications

Product Information

MFR #
LC2K1201G7
Zoro #
G1251363
UPC #
785901797968
Country of Origin
France

Dimensions

Working Height
6561.68 ft
Overall Height
2.28 in
Overall Width
3.54 in
Overall Depth
2.24 in

Details

Item
IEC Miniature Magnetic Contactor
Auxiliary Contact Form
1NC
Coil Voltage
120V AC
Number of Poles
3
Reversing Capability
Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
1
Standards
BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660
HP @ 1 Phase - 230V
1-1/2
HP @ 3 Phase - 575V
10 hp
Reversing
Yes
Enclosure NEMA Rating
No Enclosure
Series
TeSys K
Features
Preassembled with Reversing Power Busbar
Overvoltage Category
CAT III
Hold VA
4.5 VA
Switching Current
5 mA (Signalling Circuit)
Tightening Torque
0.8 to 1.3 Nm
Rated Making Capacity
144 A @ 690V (AC Power Circuit), 110 A (AC Signalling Circuit)
Mechanical Durability
5 Mcycles
Control Circuit Voltage Limits
Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C)
Rated Breaking Capacity
110 A @ 440V, 80 A @ 500V, 70 A @ 660 to 690V
Rated Short-Time Withstand Current
115 A (at 50°C for 1 s Power Circuit), 105 A (at 50°C for 5 s Power Circuit), 100 A (at 50°C for 10 s Power Circuit), 75 A (at 50°C for 30 s Power Circuit), 55 A (at 50°C for 1 min Power Circuit), 50 A (at 50°C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 25 A (at 50°C for 15 min Power Circuit)
Fuse Amps
25 A (Power Circuit), 10 A (Signalling Circuit)
Fire Rating
UL 94 V1, NF F 16-101, NF F 16-102
Watts Loss
1.3W
Shock Resistance
10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open)
IP Rating
IP20
Rated Insulation Volts
600/690V
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Operating Time
10 to 20 ms (Coil Energisation and NO Closing), 10 to 20 ms (Coil De-Energisation and NO Opening)
Application
Motor Control, Resistive Load
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Operating Speed
3600 cycles per hr
Electrical Durability
0.3 Mcycles (20 A, AC-1, Less than 440 V); 1.3 Mcycles (12 A, AC-3, Less than 440 V); 1.3 Mcycles (12 A, AC-3e, Less than 440 V)
Net Weight
0.39 kg
Switching Voltage
17 V (Signalling Circuit)
Impulse Withstand Voltage
8 kV
Signalling Circuit Frequency
Less Than 400 Hz
Inrush VA
30 VA
Impedance
3 mOhm
Max. Operating Watts
4 kW (at 480V AC 50/60 Hz), 4 kW (at 500 to 600V AC 50/60 Hz), 4 kW (at 660 to 690V AC 50/60 Hz), 3 kW (at 220 to 230V AC 50/60 Hz), 5.5 kW (at 380 to 415VAC 50/60 Hz), 5.5 kW (at 440V AC 50/60 Hz)
Environmental Attributes
Mercury Free, Toxic Heavy Metal Free
Number of Normally Open Main Contacts
3
Mounting Style
DIN Rail, Plate
Mechanical Operating Durability
5,000,000
Horsepower @ Three Phase - 240V AC
3 hp
Resistance Properties
Insulation Resistant
Full Load Current - Inductive
12:00 AM
Electrical Operating Durability
1,300,000, 300,000
Minimum Operating Temperature
-13 Degrees F
Embedded Surge Suppressor
No
Horsepower @ Three Phase - 600V AC
10 hp
Maximum Voltage Rating
690V AC
Frequency
50/60 Hz
Horsepower @ Single Phase - 120V AC
1/2 hp
Horsepower @ Three Phase - 480V AC
7 1/2 hp
Full Load Current - Resistive
20 A
NEMA Enclosure Rating
No Enclosure
Contactor Style
IEC
Maximum Operating Temperature
122 Degrees F
Includes Auxiliary Contacts
Yes
Horsepower @ Single Phase - 240V AC
1 1/2 hp
Mechanical Robustness
Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27; Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6; Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6
Auxiliary Contacts Type
Instantaneous 1 NC
Utilisation Category
AC-3; AC-1; AC-4; AC-3e
Inrush Power in VA
30 VA (at 68°F (20°C))
Control Circuit Type
AC 50/60 Hz
Rated Operational Voltage
Power circuit 690 V AC 50/60 Hz; Signalling circuit Less than or Equal to 690 V AC 50/60 Hz
Maximum Operating Rate
3600 cyc/h
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Conventional Free Air Thermal Current
20 A (at 122°F (50°C)) for power circuit; 10 A (at 122°F (50°C)) for signalling circuit
Protective Treatment
TC IEC 60068; TC DIN 50016
Heat Dissipation
1.3 W
Device Application
Control
Non Overlap Distance
0.02 in (0.5 mm)
Interlocking Type
Mechanical
Ambient Air Temperature For Storage
-58 to 176°F (-50 to 80°C)
Operating Altitude
6561.68 ft (2000 m) without derating
Contactor Application
Resistive load; Motor control
Rated Operational Current
20 A (at Less than 122°F (50°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 16 A (at Less than 158°F (70°C)) at 690 V AC AC-1 for power circuit; 12 A at Less than or Equal to 440 V AC AC-3 for power circuit; 12 A at Less than or Equal to 440 V AC AC-3e for power circuit
Control Circuit Voltage
120 V AC 50/60 Hz
Ambient Air Temperature For Operation
-13 to 122°F (-25 to 50°C)
Pole Contact Composition
3 NO

Description

Application: This product is intended for use in motor control applications and resistive load switching within specified electrical ratings.

  • Poles: 3P; Main contacts: 3 NO; Auxiliary: 1 NC (Instantaneous)
  • Action: Reversing
  • Coil voltage: 120 V AC
  • Terminals: Screw Clamp
  • Series: TeSys K
  • Maximum voltage rating: 690 V AC
  • Power circuit making capacity: Rated for operation up to the specified maximum voltage and current ratings.
  • Control circuit frequency: 50/60 Hz
  • Ambient operating temperature: -13 to 122°F (-25 to 50°C)
  • Ambient storage temperature: -58 to 176°F (-50 to 80°C)
  • Enclosure/IP: No Enclosure; IP20
  • Weight: 0.39 kg
  • Mounting: DIN Rail, Plate
  • Impulse withstand voltage: 8 kV
  • Certifications: CB Scheme; CCC; UL; CSA; EAC; CE; UKCA
  • Dimensions (Width x Depth x Height): Approximate measurements provided
  • Ratings & Reviews

    3 Reasons You Can Count On Us

    • Supplies for every job.

      Supplies for every job.

      10 million items and the exact one you need.

    • When you need it fast, count on Zoro!

      When you need it fast, count on Zoro!

      2 million products ship in 1 day.

    • Stretch your budget further.

      Stretch your budget further.

      Everyday low prices on the brands you love.