Item
IEC Miniature Magnetic Contactor
Auxiliary Contact Form
1NO
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
1
Standards
CSA, UKCA, UL Listed
Enclosure NEMA Rating
No Enclosure
HP @ 1 Phase - 230V
1-1/2
Signalling Circuit Frequency
Less Than 400 Hz
Switching Voltage
17 V (Signalling Circuit)
Environmental Attributes
Mercury Free, Toxic Heavy Metal Free
Fuse Amps
25 A (Power Circuit), 10 A (Signalling Circuit)
Fire Rating
UL 94 V1, NF F 16-101, NF F 16-102
Shock Resistance
10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open)
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Operating Speed
3600 cycles per hr
Control Circuit Voltage Limits
Operational: 0.85 to 1.1 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C)
Overvoltage Category
CAT III
Switching Current
5 mA (Signalling Circuit)
Electrical Durability
1.3 Mcycles 9 A AC-3 Less than or Equal to 440 V; 1.3 Mcycles 9 A AC-3e Less than or Equal to 440 V; 0.16 Mcycles 20 A AC-1 Less than or Equal to 690 V; 0.02 Mcycles 54 A AC-4 Less than or Equal to 440 V
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Mechanical Durability
10 Mcycles
Rated Breaking Capacity
110 A @ 415V, 440V, 220 to 230V, 380 to 400 V; 80 A @ 500V; 70 A @ 660 to 690V
Max. Operating Watts
2.2 kW (at 220 to 230V AC 50/60 Hz AC-3), 4 kW 380 to (at 415V AC 50/60 Hz AC-3), 4 kW (at 440V AC 50/60 Hz AC-3), 4 kW (at 480V AC 50/60 Hz AC-3), 4 kW (at 500 to 600V AC 50/60 Hz AC-3), 4 kW (at 660 to 690V AC 50/60 Hz AC-3), 2.2 kW (at 400V AC 50/60 Hz AC-4), 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3e), 4 kW (at 380 to 415V AC 50/60 Hz AC-3e), 4 kW (at 440V AC 50/60 Hz AC-3e), 4 kW (at 480V AC 50/60 Hz AC-3e), 4 kW (at 500 to 600V AC 50/60 Hz AC-3e), 4 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Operating Time
10 to 20 ms (Coil De-Energisation and NO Opening), 10 to 20 ms (Coil Energisation and NO Closing)
Rated Making Capacity
110 A
Application
Motor Control, Resistive Load
NEMA Enclosure Rating
No Enclosure
Horsepower @ Three Phase - 600V AC
5 hp
Resistance Properties
Insulation Resistant
Full Load Current - Resistive
20 A
Horsepower @ Three Phase - 480V AC
5 hp
Number of Normally Open Main Contacts
3
Horsepower @ Three Phase - 240V AC
3 hp
Includes Auxiliary Contacts
Yes
Horsepower @ Single Phase - 240V AC
1 1/2 hp
Maximum Voltage Rating
480V AC
Horsepower @ Single Phase - 120V AC
1/2 hp
Embedded Surge Suppressor
No
Full Load Current - Inductive
9:00 AM
Horsepower @ Three Phase - 208V AC
2 hp
Rated Operational Current
9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit; 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit
Protective Treatment
TC IEC 60068; TC DIN 50016
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Auxiliary Contacts Type
Instantaneous 1 NO
Mechanical Robustness
Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27; Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6; Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6
Conventional Free Air Thermal Current
20 A (at 140°F (60°C)) for power circuit; 10 A (at 122°F (50°C)) for signalling circuit
Device Application
Control
Control Circuit Type
AC 50/60 Hz
Utilisation Category
AC-3; AC-3e; AC-1; AC-4
Non Overlap Distance
0.02 in (0.5 mm)
Inrush Power in VA
30 VA (at 68°F (20°C))
Operating Altitude
6561.68 ft (2000 m) without derating
Contactor Application
Motor control; Resistive load
Rated Operational Voltage
Power circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz; Signalling circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz
Control Circuit Voltage
200 to 208 V AC 50/60 Hz
Maximum Operating Rate
3600 cyc/h
Impulse Withstand Voltage
8 kV
Pole Contact Composition
3 NO