Key Features

Auxiliary Contact Form
1NO
Coil Voltage
208V AC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
See all product information
Get a 10% off coupon
Free 30-day returns
Return Policy
Get 30 days to pay with Net 30
Apply Now
Unlock tax-exempt savings
Add Tax Exemption

Specifications

Product Information

MFR #
LC1K0910L7
Zoro #
G2836626
UPC #
785901720034
Country of Origin
France

Dimensions

Working Height
6561.68 ft
Overall Depth
1.97 in
Overall Width
1.73 in
Overall Height
1.73 in

Details

Item
IEC Miniature Magnetic Contactor
Auxiliary Contact Form
1NO
Coil Voltage
208V AC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
1
Standards
CSA, UKCA, UL Listed
HP @ 3 Phase - 575V
5 hp
Enclosure NEMA Rating
No Enclosure
Reversing
No
HP @ 1 Phase - 230V
1-1/2
Series
TeSys K
Impedance
3 mOhm
Signalling Circuit Frequency
Less Than 400 Hz
Switching Voltage
17 V (Signalling Circuit)
Environmental Attributes
Mercury Free, Toxic Heavy Metal Free
Fuse Amps
25 A (Power Circuit), 10 A (Signalling Circuit)
Fire Rating
UL 94 V1, NF F 16-101, NF F 16-102
Shock Resistance
10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open)
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Operating Speed
3600 cycles per hr
Control Circuit Voltage Limits
Operational: 0.85 to 1.1 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C)
Overvoltage Category
CAT III
Inrush VA
30 VA
Switching Current
5 mA (Signalling Circuit)
Electrical Durability
1.3 Mcycles 9 A AC-3 Less than or Equal to 440 V; 1.3 Mcycles 9 A AC-3e Less than or Equal to 440 V; 0.16 Mcycles 20 A AC-1 Less than or Equal to 690 V; 0.02 Mcycles 54 A AC-4 Less than or Equal to 440 V
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Mechanical Durability
10 Mcycles
Rated Breaking Capacity
110 A @ 415V, 440V, 220 to 230V, 380 to 400 V; 80 A @ 500V; 70 A @ 660 to 690V
Max. Operating Watts
2.2 kW (at 220 to 230V AC 50/60 Hz AC-3), 4 kW 380 to (at 415V AC 50/60 Hz AC-3), 4 kW (at 440V AC 50/60 Hz AC-3), 4 kW (at 480V AC 50/60 Hz AC-3), 4 kW (at 500 to 600V AC 50/60 Hz AC-3), 4 kW (at 660 to 690V AC 50/60 Hz AC-3), 2.2 kW (at 400V AC 50/60 Hz AC-4), 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3e), 4 kW (at 380 to 415V AC 50/60 Hz AC-3e), 4 kW (at 440V AC 50/60 Hz AC-3e), 4 kW (at 480V AC 50/60 Hz AC-3e), 4 kW (at 500 to 600V AC 50/60 Hz AC-3e), 4 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Watts Loss
1.3W
Operating Time
10 to 20 ms (Coil De-Energisation and NO Opening), 10 to 20 ms (Coil Energisation and NO Closing)
Rated Making Capacity
110 A
Hold VA
4.5 VA
Application
Motor Control, Resistive Load
NEMA Enclosure Rating
No Enclosure
Frequency
50/60 Hz
Phase
Three
Horsepower @ Three Phase - 600V AC
5 hp
Resistance Properties
Insulation Resistant
Full Load Current - Resistive
20 A
Horsepower @ Three Phase - 480V AC
5 hp
Number of Normally Open Main Contacts
3
Horsepower @ Three Phase - 240V AC
3 hp
Includes Auxiliary Contacts
Yes
Horsepower @ Single Phase - 240V AC
1 1/2 hp
Mounting Style
DIN Rail
Maximum Voltage Rating
480V AC
Horsepower @ Single Phase - 120V AC
1/2 hp
Embedded Surge Suppressor
No
Full Load Current - Inductive
9:00 AM
Horsepower @ Three Phase - 208V AC
2 hp
Contactor Style
IEC
Rated Operational Current
9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit; 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit
Protective Treatment
TC IEC 60068; TC DIN 50016
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Auxiliary Contacts Type
Instantaneous 1 NO
Mechanical Robustness
Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27; Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6; Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6
Conventional Free Air Thermal Current
20 A (at 140°F (60°C)) for power circuit; 10 A (at 122°F (50°C)) for signalling circuit
Device Application
Control
Control Circuit Type
AC 50/60 Hz
Utilisation Category
AC-3; AC-3e; AC-1; AC-4
Non Overlap Distance
0.02 in (0.5 mm)
Inrush Power in VA
30 VA (at 68°F (20°C))
Operating Altitude
6561.68 ft (2000 m) without derating
Contactor Application
Motor control; Resistive load
Rated Operational Voltage
Power circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz; Signalling circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz
Control Circuit Voltage
200 to 208 V AC 50/60 Hz
Heat Dissipation
1.3 W
Maximum Operating Rate
3600 cyc/h
Impulse Withstand Voltage
8 kV
Pole Contact Composition
3 NO

Description

The IEC Miniature Magnetic Contactor is a compact, electrically actuated switch rated for operation within the specified voltage and current ranges per IEC standards. It is a three-pole, non-reversing device with three normally open main contacts and one normally open auxiliary contact, energized by a 208 V AC coil. Rated for use with motors and resistive loads within specified parameters. Compatible with DIN-rail mounting as per product specifications, with screw-clamp terminals.

Coil voltage: 208 V AC; Control circuit: AC 50/60 Hz; Poles/Main contacts: 3P, 3 NO; Auxiliary contact: Instantaneous 1 NO

  • Application: suitable for motor control and resistive load applications within specified fuse ratings as defined by IEC 60947/VDE 0660 standards
  • Maximum voltage rating: rated for operation up to a maximum of 480 V AC under specified conditions
  • Embedded surge suppressor: does not include an integrated surge suppression device; compatibility with external surge protection should be verified based on application needs
  • Enclosure: designed for installation in enclosures compliant with applicable safety standards
  • Mounting: DIN Rail; Terminals: Screw Clamp; Series: TeSys K
  • Rated operational current: 9 A (AC-3 up to 440 V), 20 A (AC-1 up to 690 V)
  • Full load amps: capable of handling full load currents as specified when operated within the recommended parameters
  • Inrush/hold power: Inrush 30 VA; Hold-in 4.5 VA
  • Dimensions: Width 1.73 in; Height 1.73 in; Depth 1.97 in
  • Certifications: UL Listed; CSA; CE; UKCA; CB Scheme; CCC; EAC
  • Ratings & Reviews

    3 Reasons You Can Count On Us

    • Supplies for every job.

      Supplies for every job.

      10 million items and the exact one you need.

    • When you need it fast, count on Zoro!

      When you need it fast, count on Zoro!

      2 million products ship in 1 day.

    • Stretch your budget further.

      Stretch your budget further.

      Everyday low prices on the brands you love.