Item
IEC Miniature Magnetic Contactor
Auxiliary Contact Form
1NO
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
1
Standards
CSA, UKCA, UL Listed
Enclosure NEMA Rating
No Enclosure
HP @ 1 Phase - 230V
1-1/2
HP @ 3 Phase - 575V
10 hp
Frame / Series / Class / Code
TeSys
Operating Speed
3600 cycles per hr
Rated Making Capacity
110 A (AC Signalling Circuit), 144 A (AC Power Circuit)
Fire Rating
UL 94 V1, NF F 16-101, NF F 16-102
Switching Current
5 mA (Signalling Circuit)
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Control Circuit Voltage Limits
Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.1 to 0.75 Uc (at 50°C)
Application
Motor Control, Resistive Load
Electrical Durability
1.3 Mcycles 12 A AC-3 Less than or Equal to 440 V; 1.3 Mcycles 12 A AC-3e Less than or Equal to 440 V; 0.3 Mcycles 20 A AC-1 Less than or Equal to 690 V; 0.02 Mcycles 72 A AC-4 Less than or Equal to 440 V
Mechanical Durability
10 Mcycles
Overvoltage Category
CAT III
Switching Voltage
17 V (Signalling Circuit)
Rated Breaking Capacity
110 A @ 440V, 80 A @ 500V, 70 A @ 660 to 690V
Impulse Withstand Voltage
8 kV
Rated Insulation Volts
600/690V
Fuse Amps
25 A (Power Circuit), 10 A (Signalling Circuit)
Environmental Attributes
Mercury Free, Toxic Heavy Metal Free
Operating Time
30 to 40 ms (Coil Energisation and NO Closing), 10 ms (Coil De-Energisation and NO Opening)
Tightening Torque
0.8 to 1.3 Nm
Maximum Voltage Rating
690V AC
Horsepower @ Three Phase - 480V AC
7 1/2 hp
Includes Auxiliary Contacts
Yes
Full Load Current - Resistive
20 A
Full Load Current - Inductive
12:00 AM
NEMA Enclosure Rating
No Enclosure
Horsepower @ Three Phase - 600V AC
10 hp
Resistance Properties
Insulation Resistant
Maximum Operating Temperature
122 Degrees F
Number of Normally Open Main Contacts
3
Embedded Surge Suppressor
No
Mounting Style
DIN Rail, Plate
Horsepower @ Three Phase - 240V AC
3 hp
Mechanical Operating Durability
10,000,000
Horsepower @ Single Phase - 240V AC
2 hp
Minimum Operating Temperature
-13 Degrees F
Horsepower @ Single Phase - 120V AC
1/2 hp
Contactor Application
Resistive load; Motor control
Ambient Air Temperature For Storage
-58 to 176°F (-50 to 80°C)
Hold-In Power Consumption in W
3 W 68°F (20°C)
Control Circuit Type
DC standard
Auxiliary Contacts Type
Instantaneous 1 NO
Rated Operational Current
12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit; 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit
Maximum Operating Rate
3600 cyc/h
Conventional Free Air Thermal Current
20 A (at 140°F (60°C)) for power circuit; 10 A (at 122°F (50°C)) for signalling circuit
Rated Operational Voltage
Power circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz; Signalling circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz
Inrush Power in W
3 W 68°F (20°C)
Utilisation Category
AC-3; AC-3e; AC-1; AC-4
Ambient Air Temperature For Operation
-40 to 158°F (-40 to 70°C) at Uc
Operating Altitude
6561.68 ft (2000 m) without derating
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Rated Short-Time Withstand Current
115 A (at 50°C for 1 s Power Circuit), 105 A (at 50°C for 5 s Power Circuit), 100 A (at 50°C for 10 s Power Circuit), 75 A (at 50°C for 30 s Power Circuit), 55 A (at 50°C for 1 min Power Circuit), 50 A (at 50°C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 25 A (at 50°C for 15 min Power Circuit)
Pole Contact Composition
3 NO