- Item
- Photoelectric Sensor
- Sensing Method
- Multimode
- Electrical Connection
- M16
- Style
- Rectangular
- Orientation
- Right Angle
- Material
- plastic
- Operating Mode
- Selectable Light On/Dark On
- IP Rating
- IP65, IP67
- Output Circuit Type
- NPN and PNP
- Output Circuit Number of Wires
- 3
- DC Voltage Rating
- 12-24V DC
- Standards
- CE, CSA Certified, IEC 60529, RoHS, UL Listed
- Power Requirement - Rectangular Photoelectric Sensor
- 12 to 24V DC
- Max. Sensing Distance
- 60m
- Max. Load Current
- 100 mA
- Max. Sensing Distance - Rectangular Photoelectric Sensor
- 60 m
- Body Material
- PBT
- Operating Temp. Range
- -25 Degrees to 55 Degrees C
- Operating Frequency
- 250 Hz
- Light Source
- Infrared LED
- Response Time
- 25 msec
- Power Requirement
- 12 to 24VDC
- Features
- Background Suppression, Overload Protection, Polarized Retro-Reflective, Programmable, Retro-Reflective, Reverse Polarity Protection, Short Circuit Protection
- Current Consumption
- <= 35 mA no-load
- Switching Capacity In Ma
- <= 100 mA overload and short-circuit protection)
- Enclosure Material
- PBT
- Maximum Voltage Drop
- <1.5 V closed state)
- Ambient Air Temperature For Operation
- -25-55°C
- Maximum Delay Response
- 2 ms
- Maximum Delay Recovery
- 2 ms
- Status Led
- 1 LED green)supply || 1 LED red)instability || 1 LED yellow)output state
- Sensor Design
- compact 92 x 71
- Emission
- infrared diffuse || infrared diffuse with background suppression || infrared thru beam || red polarised reflex
- Output Type
- solid state
- Detection System
- multimode
- Vibration Resistance
- 7 gn +/- 1.5 mm 10-55 Hz) IEC 60068-2-6
- Sensor Name
- XUX
- Maximum Delay First Up
- 200 ms
- Cable Entry
- 1 entry for M16 x 1.5 cable gland 7-10 mm
- Electronic Sensor Type
- photo-electric sensor
- Setting-Up
- self-teaching
- Maximum Sensing Distance
- 15 m polarised reflex || 3 m diffuse || 60 m thru beam || 1.3 m diffuse with background suppression
- Shock Resistance
- 30 gn 11 ms) IEC 60068-2-27
- [Sn] Nominal Sensing Distance
- 11-11 m polarised reflex need reflector XUZC50 || 40-40 m thru beam need a transmitter XUX0AKSAT16T || 2-2 m diffuse || 1.3-1.3 m diffuse with background suppression
- [Us] Rated Supply Voltage
- 12...24 V DC reverse polarity protection
- Switching Frequency
- 250 Hz
- Ambient Air Temperature For Storage
- -40-70°C
- Add On Output
- with alarm output, <= 100 mA overload and short-circuit protection
- Series Name
- general purpose multimode
- Supply Circuit Type
- DC
- Lens Material
- PMMA
- Type Of Output Signal
- discrete
- Sensing Distance - Minimum
- 0 m
- Electrical Installation Type
- Screw Terminal
- Product Type
- Photoelectric Sensor
- Load Current - Maximum
- 100 mA
- Operating Temperature - Maximum
- 131 Degrees F
- Includes Indicator Lights
- Indicator Lights Included
- Output Circuit Contact Form
- 1NO/1NC
- Series
- XU
- Operating Temperature - Minimum
- -13 Degrees F
- Sensing Distance - Maximum
- 11 m