Key Features

AC Contact Rating - Relay
1 A AC-15, 3 A AC-1, 3 A AC-15, 5 A AC-1
DC Contact Rating - Relay
5 A DC-1; 3 A DC-13; 3 A DC-1; 1 A DC-13
Mounting - Relay
DIN Rail
Input Power Consumption (Burden)
4.5 W
Delay Time - Relay
Sync time between inputs: 0.5s 2s 4 s
See all product information
Unlock 30-day payment terms
Unlock 30-day payment terms
Business customers can apply for Net 30—no fees, no interest, fast approval. Terms apply.
Create Account
Get 10% off your order
Get 10% off your order
Sign up for our email list and receive your promo code via email.

Specifications

Product Information

MFR #
XPSUDN13AP
Zoro #
G003529055
UPC #
-
Country of Origin
Indonesia

Dimensions

Body Depth - Relay
4.72 in
Height
100 mm
Body Width - Relay
1.77 in
Overall Depth
3.9 in
Depth
120 mm
Overall Height - Relay
3.94 in
Body Height - Relay
3.94 in
Width
45 mm
Body Width
1.77 in
Body Depth
4.72 in
Body Height
3.94 in

Details

Item
Force
AC Contact Rating - Relay
1 A AC-15, 3 A AC-1, 3 A AC-15, 5 A AC-1
DC Contact Rating - Relay
5 A DC-1; 3 A DC-13; 3 A DC-1; 1 A DC-13
Mounting - Relay
DIN Rail
Input Power Consumption (Burden)
4.5 W
Delay Time - Relay
Sync time between inputs: 0.5s 2s 4 s
For Use With
Guard Switch, Magnetic Switch, Monitoring Emergency Stop, PNP Sensors, Proximity Safety Switch, RFID Safety Switch or Safety Light Curtain
IP Rating
IP20; IP40; IP54
Response Time
20 msec
Power Consumption
4.5 W
Standards
CCC, cULus Listed, EAC, IEC 60947-5-1, IEC 61508-1/2/3, IEC 62061, ISO 13849-1, TUV Certified
Environmental Protection
Dust & Splash Resistant
Mounting Style
DIN Rail
Application
Emergency Stop
Input Voltage
24V AC/DC
Electrical Connection - Relay
Screw Terminal, Terminal Block Removable
Weight
12.35 oz
Number of Input Channels
6
Maximum Operating Temperature
185 Degrees F
Contact Rating (DC)
1 A @ 13V (NC), 3 A @ 1V (NC), 3 A @ 13V (NO), 5 A @ 1V (NO)
Delay Time
0.5 sec, 2 sec, 4 sec
Delay Type
Adjustable
Electrical Connection
Screw Terminal, Terminal Block Removable
Frequency
50/60 Hz
Minimum Operating Temperature
-13 Degrees F
Contact Rating (AC)
1 A @ 15V (NC), 3 A @ 1V (NC), 3 A @ 15V (NO), 5 A @ 1V (NO)
Safety Reliability Data
Dcavg Greater Than= 99% Conforming to ISO 13849-1, HFT = 1 Conforming to IEC 61508-1, HFT = 1 Conforming to IEC 62061, MTTFd Greater Than 30 years Conforming to ISO 13849-1, PFHd = 0.88E-09 Conforming to IEC 61508-1, PFHd = 0.88E-09 Conforming to IEC 62061, PFHd = 0.88E-09 Conforming to ISO 13849-1, SFF Greater Than 99% Conforming to IEC 61508-1, SFF Greater Than 99% Conforming to IEC 62061, Type = B Conforming to IEC 61508-1
Input Protection Type
internal, electronic
Ip Degree Of Protection
IP20 terminals)EN/IEC 60947-1 || IP40 housing)EN/IEC 60947-1 || IP54 mounting area)EN/IEC 60947-1
[Ith] Conventional Free Air Thermal Current
16 A
Synchronisation Time Between Inputs
0.5 s || 2 s || 2.2 s || 4 s
Number Of Outputs
7 on/off configurable pulsed output
Maximum Response Time On Input Open
20 ms
Type Of Start
automatic/manual/monitored
Local Signalling
for power ON LED (green) || for error LED (red) || for start LED (yellow) || for safety status LED (yellow) || for safety input S12 LED (yellow) || for safety input S13 LED (yellow) || for safety input S22 LED (yellow) || for safety input S23 LED (yellow) || for safety input S32 LED (yellow) || for safety input S33 LED (yellow) || for safety input S42 LED (yellow) || for safety input S43 LED (yellow) || for safety input S52 LED (yellow) || for safety input S53 LED (yellow) || for safety input S62 LED (yellow) || for safety input S73 LED (yellow)
Input Compatibility
normally closed circuit ISO 14119 || XC limit switch ISO 14119 || mechanical contact ISO 14119 || normally closed circuit ISO 13850 || antivalent pair ISO 14119 || OSSD pair IEC 61496-1-2 || 3-wire proximity sensors PNP
Maximum Line Resistance
500 Ohm
Ambient Air Temperature For Operation
-25-50°C at 24 V AC || -25-55°C at 24 V DC
Associated Fuse Rating
10 A gG NO relay output circuit IEC 60947-1 || 4 A gG NC relay output circuit IEC 60947-1
Relative Humidity
5-95 % non-condensing
Rated Supply Voltage
24 V AC - 15 to 10%; 24 V DC - 20 to 20%
[Us] Rated Supply Voltage
24 V AC - 15...10 % || 24 V DC - 20...20 %
Power Consumption In Va
10.5 VA 24 V AC 50/60 Hz
Number Of Inputs
6 safety input 24 V DC 5
[Ie] Rated Operational Current
5 A AC-1 for normally open relay contact || 3 A AC-15 for normally open relay contact || 5 A DC-1 for normally open relay contact || 3 A DC-13 for normally open relay contact || 3 A AC-1 for normally closed relay contact || 1 A AC-15 for normally closed relay contact || 3 A DC-1 for normally closed relay contact || 1 A DC-13 for normally closed relay contact
Product Or Component Type
safety module
Electrical Circuit Type
NC pair || PNP pair || antivalent pair || OSSD pair
Power Consumption In W
4.5 W 24 V DC
Mounting Support
35 mm symmetrical DIN rail
Minimum Output Voltage
12 V relay output
[Uimp] Rated Impulse Withstand Voltage
4 kV II EN/IEC 60947-1
Product Certifications
TUV || cULus
Input/Output Type
semiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related
Function Of Module
emergency stop button with 2 NC contacts || guard monitoring with 1 or 2 limit switches || monitoring 2 PNP sensors || magnetic switch monitoring || light curtain monitoring || RFID switch || monitoring of electro-sensitive protection equipment (ESPE) || proximity sensor monitoring
Connections - Terminals
removable screw terminal block, 0.2...2.5 mm² solid or flexible || removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor || removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor || removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel || removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
Safety Level
can reach PL e/category 4 for normally open relay contact ISO 13849-1 || can reach SILCL 3 for normally open relay contact IEC 62061 || can reach SIL 3 for normally open relay contact IEC 61508 || can reach PL c/category 1 for normally closed relay contact ISO 13849-1 || can reach SILCL 1 for normally closed relay contact IEC 62061 || can reach SIL 1 for normally closed relay contact IEC 61508
Safety Module Name
XPSUDN
Rated Operational Current
5 A AC-1 for normally open relay contact; 3 A AC-15 for normally open relay contact; 5 A DC-1 for normally open relay contact; 3 A DC-13 for normally open relay contact; 3 A AC-1 for normally closed relay contact; 1 A AC-15 for normally closed relay contact; 3 A DC-1 for normally closed relay contact; 1 A DC-13 for normally closed relay contact
[Ui] Rated Insulation Voltage
250 V 2)EN/IEC 60947-1
Minimum Output Current
10 mA relay output
Auxiliary Contact Composition
3 NO + 1 NC
Safety Inputs
6 safety input 24 V DC 5 mA
Ambient Air Temperature For Storage
-25-85°C
Safety Module Application
monitoring antivalent contacts || for emergency stop, guard and light curtain monitoring
Compatible Product Type
Guard Switch, Magnetic Switch, Monitoring Emergency Stop, PNP Sensors, Proximity Safety Switch, RFID Safety Switch or Safety Light Curtain

Description

Force, Delay Time 0.5 sec, 2 sec, 4 sec, Delay Type Adjustable, Electrical Connection Screw Terminal, Terminal Block Removable, IP Rating IP20; IP40; IP54, Input Voltage 24V AC/DC, Mounting Style DIN Rail, Response Time 20 msec, Standards CCC, cULus Listed, EAC, IEC 60947-5-1, IEC 61508-1/2/3, IEC 62061, ISO 13849-1, TUV Certified, Contact Rating (AC) 1 A @ 15V (NC), 3 A @ 1V (NC), 3 A @ 15V (NO), 5 A @ 1V (NO), Contact Rating (DC) 1 A @ 13V (NC), 3 A @ 1V (NC), 3 A @ 13V (NO), 5 A @ 1V (NO)

Ratings & reviews

3 reasons you can count on us

  • Supplies for every job.

    13 million items and the exact one you need.

  • When you need it fast, count on Zoro!

    4.5 million products ship in 1 day.

  • Stretch your budget further.

    Everyday low prices on the brands you love.