IEC Magnetic Contactor, 1NC/1NO, 220V AC, 3 P, Non-Reversing, Screw Clamp

  • Mfr # LC1D18M7

  • Zoro # G0478296


product price:  $179.99
/ea
Free Shipping & Returns

Key Features

Auxiliary Contact Form
1NC/1NO
Coil Voltage
220V AC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
See all product information
Get a 10% off coupon
Free 30-day returns
Return Policy
Get 30 days to pay with Net 30
Apply Now
Unlock tax-exempt savings
Add Tax Exemption

Specifications

Product Information

MFR #
LC1D18M7
Zoro #
G0478296
UPC #
785901213284
Country of Origin
Indonesia

Dimensions

Working Height
Up to 9842.52 ft
Overall Depth
3.39 in
Overall Height
3.03 in
Overall Width
1.77 in

Details

Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Coil Voltage
220V AC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
Series
TeSys Deca
HP @ 3 Phase - 575V
15 hp
Enclosure NEMA Rating
No Enclosure
Frame / Series / Class / Code
TeSys
Reversing
No
Switching Current
5 mA (Signalling Circuit)
Signalling Circuit Frequency
25 to 400 Hz
Includes Protective Cover
Yes
Non-Overlap Time
1.5 ms
Electrical Durability
1.65 Mcycles (18 A, AC-3, Less than 440 V); 1 Mcycles (32 A, AC-1, Less than 440 V); 1.65 Mcycles (18 A, AC-3e, Less than 440 V)
Environmental Attributes
Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Switching Voltage
17 V (Signalling Circuit)
Rated Making Capacity
140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 300 A @ 440V (Power Circuit)
Application
Motor Control, Resistive Load
Control Circuit Voltage Limits
Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Operating Speed
3600 cycles per hr
Rated Breaking Capacity
300 A @ 440V
Net Weight
0.33 kg
Watts Loss
2 to 3W
Fuse Amps
10 A (Signalling Circuit), 50 A (Type 1 Power Circuit), 35 A (Type 2 Power Circuit)
Tightening Torque
1.7 Nm
Operating Time
12 to 22 ms (Closing), 4 to 19 ms (Opening)
IP Rating
IP20
Fire Rating
UL 94 V1
Inrush VA
70 VA
Impedance
2.5 mOhm
Overvoltage Category
CAT III
Mechanical Durability
15 Mcycles
Shock Resistance
15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Features
Without Built-In Suppressor Module
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Rated Insulation Volts
600/690V
Max. Operating Watts
4 kW (at 220 to 230V AC 50/60 Hz AC-3), 7.5 kW (at 380 to 400V AC 50/60 Hz AC-3), 9 kW (at 415 to 440V AC 50/60 Hz AC-3), 10 kW (at 500V AC 50/60 Hz AC-3), 10 kW (at 660 to 690V AC 50/60 Hz AC-3), 4 kW (at 400V AC 50/60 Hz AC-4), 4 kW (at 220 to 230V AC 50/60 Hz AC-3e), 7.5 kW (at 380 to 400V AC 50/60 Hz AC-3e), 9 kW (at 415 to 440V AC 50/60 Hz AC-3e), 10 kW (at 500V AC 50/60 Hz AC-3e), 10 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Impulse Withstand Voltage
6 kV
Hold VA
7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Rated Short-Time Withstand Current
145 A (at 40°C for 10 s Power Circuit), 240 A (at 40°C for 1 s Power Circuit), 40 A (at 40°C for 10 min Power Circuit), 84 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Horsepower @ Three Phase - 240V AC
5 hp
Horsepower @ Three Phase - 208V AC
5 hp
Number of Normally Open Main Contacts
3
NEMA Enclosure Rating
No Enclosure
Horsepower @ Three Phase - 480V AC
10 hp
Frequency
50/60 Hz
Resistance Properties
Fire Resistant, Insulation Resistant
Maximum Operating Temperature
140 Degrees F
Full Load Current - Inductive
18 A
Minimum Operating Temperature
-40 Degrees F
Electrical Operating Durability
1,000,000, 1,650,000
Mounting Style
DIN Rail, Plate
Horsepower @ Single Phase - 240V AC
3 hp
Horsepower @ Single Phase - 120V AC
1 hp
Horsepower @ Three Phase - 600V AC
15 hp
Embedded Surge Suppressor
No
Maximum Voltage Rating
690V AC
Includes Auxiliary Contacts
Yes
Mechanical Operating Durability
15,000,000
Phase
Three
Contactor Style
IEC
Fire Resistance
1562°F (850°C) IEC 60695-2-1
Operating Altitude
0 to 9842.52 ft (0 to 3000 m)
Power Dissipation Per Pole
2.5 W AC-1; 0.8 W AC-3; 0.8 W AC-3e
Inrush Power in VA
70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Contactor Application
Resistive load; Motor control
Heat Dissipation
2 to 3 W at 50/60 Hz
Mechanical Robustness
Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor open 10 Gn for 11 ms); Shocks contactor closed 15 Gn for 11 ms)
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Contact Compatibility
M2
Auxiliary Contacts Type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
Climatic Withstand
IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat
Rated Operational Voltage
Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
Protective Cover
With
Utilisation Category
AC-1; AC-4; AC-3; AC-3e
Rated Operational Current
18 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 32 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 18 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Protective Treatment
THIEC 60068-2-30
Control Circuit Type
AC 50/60 Hz standard
Pole Contact Composition
3 NO
Pollution Degree
3
Control Circuit Voltage
220 V AC 50/60 Hz
Compatibility Code
LC1D
Conventional Free Air Thermal Current
10 A (at 140°F (60°C)) for signalling circuit; 32 A (at 140°F (60°C)) for power circuit
Maximum Operating Rate
3600 cyc/h 140°F (60°C)
Full Load Current - Resistive
32 A
Ambient Air Temperature For Operation
-40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating

Description

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 220V AC, Number of Poles 3, Full Load Current - Inductive 18 A, Reversing Capability Non-Reversing, Overall Height 3.03 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC, Horsepower @ Three Phase - 240V AC 5 hp

Ratings & reviews

3 reasons you can count on us

  • Supplies for every job.

    Supplies for every job.

    10 million items and the exact one you need.

  • When you need it fast, count on Zoro!

    When you need it fast, count on Zoro!

    2 million products ship in 1 day.

  • Stretch your budget further.

    Stretch your budget further.

    Everyday low prices on the brands you love.