Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
HP @ 3 Phase - 575V
100 hp
Enclosure NEMA Rating
No Enclosure
HP @ 1 Phase - 230V
Not rated
Mechanical Durability
8 Mcycles
Switching Voltage
17 V (Signalling Circuit)
Fuse Amps
250 A (Type 1 Power Circuit), 200 A (Type 2 Power Circuit), 10 A (Signalling Circuit)
Rated Breaking Capacity
1100 A @ 440V
Tightening Torque
1.2 Nm (Control Circuit), 12 Nm (Power Circuit)
Max. Operating Watts
30 kW (at 220 to 230V AC 50/60 Hz AC-3), 55 kW (at 380 to 400V AC 50/60 Hz AC-3), 59 kW 415 to (at 440V AC 50/60 Hz AC-3), 75 kW (at 500V AC 50/60 Hz AC-3), 80 kW (at 660 to 690V AC 50/60 Hz AC-3), 65 kW (at 1000V AC 50/60 Hz AC-3), 18.5 kW (at 400V AC 50/60 Hz AC-4), 30 kW (at 220 to 230V AC 50/60 Hz AC-3e), 55 kW (at 380 to 400V AC 50/60 Hz AC-3e), 59 kW 415 to (at 440V AC 50/60 Hz AC-3e), 75 kW (at 500V AC 50/60 Hz AC-3e), 80 kW (at 660 to 690V AC 50/60 Hz AC-3e), 65 kW (at 1000V AC 50/60 Hz AC-3e)
Rated Insulation Volts
600/1000V (Power Circuit), 600/690V (Signalling Circuit)
Operating Speed
2400 cycles per hr
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Environmental Attributes
Mercury Free, PVC Free, Pollution Degree 3
Includes Protective Cover
Yes
Rated Short-Time Withstand Current
250 A (at 40°C for 10 min Power Circuit), 550 A (at 40°C for 1 min Power Circuit), 950 A (at 40°C for 10 s Power Circuit), 1100 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Control Circuit Voltage Limits
Drop-Out AC: 0.3 to 0.5 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.15 Uc (at -40-55°C 50/60 Hz), 1 to 1.15 Uc (at 55-70°C 50/60 Hz)
Shock Resistance
15 G for 11 ms (Contactor Closed), 6 G for 11 ms (Contactor Open)
Switching Current
5 mA (Signalling Circuit)
Features
Built-In Bi-Directional Peak Limiting Diode Suppressor
Signalling Circuit Frequency
25 to 400 Hz
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Application
Motor Control, Resistive Load
Overvoltage Category
CAT III
Electrical Durability
0.8 Mcycles (200 A, AC-1, Less than 440 V); 0.95 Mcycles (115 A, AC-3, Less than 440 V); 0.95 Mcycles (115 A, AC-3e, Less than 440 V)
Operating Time
6 to 20 ms (Opening), 20 to 50 ms (Closing)
Impulse Withstand Voltage
8 kV
Rated Making Capacity
1260 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
Horsepower @ Single Phase - 120V AC
Not Rated
Electrical Operating Durability
800,000, 950,000
Mechanical Operating Durability
8,000,000
Minimum Operating Temperature
-40 Degrees F
Horsepower @ Three Phase - 600V AC
100 hp
Horsepower @ Single Phase - 240V AC
3 hp
Number of Normally Open Main Contacts
3
Embedded Surge Suppressor
Yes
Full Load Current - Resistive
200 A
Full Load Current - Inductive
115 A
Horsepower @ Three Phase - 208V AC
30 hp
Maximum Voltage Rating
1000V AC
Horsepower @ Three Phase - 480V AC
75 hp
Mounting Style
DIN Rail, Plate
NEMA Enclosure Rating
No Enclosure
Horsepower @ Three Phase - 240V AC
40 hp
Maximum Operating Temperature
140 Degrees F
Resistance Properties
Fire Resistant, Insulation Resistant
Includes Auxiliary Contacts
Yes
Conventional Free Air Thermal Current
200 A (at 60°C Power Circuit)