IEC Magnetic Contactor, No Auxiliary Contacts, 120V AC, 4 P, Non-Reversing, Screw Clamp

  • Mfr # LC1DT25G7

  • Zoro # G0569007


product price:  $162.99
/ea
Free Shipping & Returns

Key Features

Auxiliary Contact Form
1NC/1NO
Coil Voltage
120V AC
Number of Poles
4
Full Load Amps-Inductive
25 A
Full Load Amps-Resistive
25 A
See all product information
Get a 10% off coupon
Free 30-day returns Return Policy
Get 30 days to pay with Net 30 Apply Now
Unlock tax-exempt savings Add Tax Exemption

Specifications

Product Information

MFR #
LC1DT25G7
Zoro #
G0569007
UPC #
785901503217
Country of Origin
Indonesia

Dimensions

Working Height
Up to 9842.52 ft
Overall Depth
3.62 in
Overall Width
1.77 in
Overall Height
3.35 in

Details

Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Coil Voltage
120V AC
Number of Poles
4
Full Load Amps-Inductive
25 A
Full Load Amps-Resistive
25 A
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UL 508, UL Listed
Frame / Series / Class / Code
TeSys
Reversing
No
Enclosure NEMA Rating
No Enclosure
Series
TeSys Deca
Features
Without Built-In Suppressor Module
Inrush VA
70 VA
Switching Current
5 mA (Signalling Circuit)
IP Rating
IP20
Net Weight
0.365 kg
Includes Protective Cover
Yes
Rated Making Capacity
140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 250 A @ 440V (Power Circuit)
Mechanical Durability
15 Mcycles
Impedance
2.5 mOhm
Rated Breaking Capacity
250 A @ 440V
Signalling Circuit Frequency
25 to 400 Hz
Tightening Torque
1.7 Nm
Environmental Attributes
Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Fire Rating
UL 94 V1
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Operating Time
4 to 19 ms (Opening), 12 to 22 ms (Closing)
Impulse Withstand Voltage
6 kV
Electrical Durability
0.8 Mcycles (25 A, AC-1, Less than 440 V)
Shock Resistance
10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Rated Short-Time Withstand Current
30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Fuse Amps
10 A (Signalling Circuit), 40 A (Type 1 Power Circuit), 25 A (Type 2 Power Circuit)
Operating Speed
3600 cycles per hr
Application
Resistive Load
Watts Loss
2 to 3W
Non-Overlap Time
1.5 ms
Rated Insulation Volts
600/690V
Switching Voltage
17 V (Signalling Circuit)
Hold VA
7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Control Circuit Voltage Limits
Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Overvoltage Category
CAT III
Includes Auxiliary Contacts
Yes
Mechanical Operating Durability
15,000,000
Full Load Current - Resistive
25 A
Maximum Voltage Rating
690V AC
Frequency
50/60 Hz
Resistance Properties
Fire Resistant, Insulation Resistant
Maximum Operating Temperature
140 Degrees F
NEMA Enclosure Rating
No Enclosure
Number of Normally Open Main Contacts
4
Mounting Style
DIN Rail, Plate
Full Load Current - Inductive
25 A
Contactor Style
IEC
Minimum Operating Temperature
-40 Degrees F
Embedded Surge Suppressor
No
Electrical Operating Durability
800,000
Conventional Free Air Thermal Current
10 A (at 60°C Signalling Circuit), 25 A (at 60°C Power Circuit)

Description

The IEC Magnetic Contactor, TeSys Deca, is a 4-pole, non-reversing, coil-driven switch rated for operation within specified load types. It is rated for use with a 120 V AC coil; includes 4 main normally open contacts and 2 auxiliary contacts as specified. The unit uses screw clamp terminals, is designed to meet IP20 standards when properly installed, and includes a protective cover suitable for standard applications. Mounting options: compatible with DIN rail mounting or plate mounting per IEC standards.

Key features

  • Coil Voltage: 120 V AC
  • Poles/Main Contacts: 4 poles; 4 normally open main contacts
  • Auxiliary Contacts: 2
  • Reversing: Non-Reversing
  • Series/Frame: TeSys; TeSys Deca
  • Electrical rating: 690 V AC max; 300 V DC
  • Full Load Amps: 25 A (inductive and resistive)
  • Enclosure/Protection: IP20 design; protective cover included
  • Mounting: compatible with DIN rail mounting or plate mounting per IEC standards
  • Dimensions (W x H x D): 1.77 in x 3.35 in x 3.62 in
  • Net Weight: 0.365 kg
  • Durability: Mechanical 15 Mcycles; Electrical 0.8 Mcycles
  • Operating times: Opening 4–19 ms; Closing 12–22 ms
  • Impedance: 2.5 mΩ
  • Impulse Withstand Voltage: 6 kV
  • Environmental/Standards: Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3; Standards include UL 508, UL Listed, EN 60947-4-1, EN 60947-5-1
  • Other: Inrush VA 70 VA; Hold VA 7.5 VA (60 Hz, 20°C) / 7 VA (50 Hz, 20°C); Signalling Frequency 25–400 Hz; Operating frequency 50/60 Hz
  • Ratings & reviews

    3 reasons you can count on us

    • Supplies for every job.

      Supplies for every job.

      10 million items and the exact one you need.

    • When you need it fast, count on Zoro!

      When you need it fast, count on Zoro!

      2 million products ship in 1 day.

    • Stretch your budget further.

      Stretch your budget further.

      Everyday low prices on the brands you love.