AC Contact Rating - Relay
|
1 A AC-15, 3 A AC-1, 3 A AC-15, 5 A AC-1
|
DC Contact Rating - Relay
|
5 A DC-1; 3 A DC-13; 3 A DC-1; 1 A DC-13
|
Mounting - Relay
|
DIN Rail
|
Input Power Consumption (Burden)
|
3 W
|
Delay Time - Relay
|
Sync time between inputs: 0.5s 2s 4 s
|
Environmental Protection
|
Dust & Splash Resistant
|
Item
|
Force
|
Standards
|
IEC 60947-5-1 || IEC 61508-1 functional safety standard || IEC 61508-2 functional safety standard || IEC 61508-3 functional safety standard || IEC 61508-4 functional safety standard || IEC 61508-5 functional safety standard || IEC 61508-6 functional safety standard || IEC 61508-7 functional safety standard || ISO 13849-1 functional safety standard || IEC 62061 functional safety standard
|
Electrical Connection - Relay
|
Screw Terminal, Terminal Block Removable
|
Electrical Connection Type
|
Screw
|
Relay Mounting Style
|
DIN-Rail
|
Input Compatibility
|
normally closed circuit ISO 14119 || XC limit switch ISO 14119 || mechanical contact ISO 14119 || normally closed circuit ISO 13850 || antivalent pair ISO 14119 || OSSD pair IEC 61496-1-2 || 3-wire proximity sensors PNP
|
[Us] Rated Supply Voltage
|
24 V AC - 15...10 % || 24 V DC - 20...20 %
|
Input/Output Type
|
semiconductor output 24 V DC, 20 mA Z2, not safety-related || pulsed output for diagnostics 24 V DC, 20 mA Z1, not safety-related
|
Product Certifications
|
TUV || cULus
|
Electrical Circuit Type
|
NC pair || PNP pair || antivalent pair || OSSD pair
|
Input Protection Type
|
internal, electronic
|
Time Delay Range
|
0...900 s off
|
Safety Level
|
can reach PL e/category 4 for normally open relay contact ISO 13849-1 || can reach SILCL 3 for normally open relay contact IEC 62061 || can reach SIL 3 for normally open relay contact IEC 61508 || can reach PL c/category 1 for normally closed relay contact ISO 13849-1 || can reach SILCL 1 for normally closed relay contact IEC 62061 || can reach SIL 1 for normally closed relay contact IEC 61508
|
Minimum Output Current
|
20 mA relay output
|
Minimum Output Voltage
|
24 V relay output
|
Mounting Support
|
35 mm symmetrical DIN rail
|
[Uimp] Rated Impulse Withstand Voltage
|
4 kV II EN/IEC 60947-1
|
Ip Degree Of Protection
|
IP54 mounting area)EN/IEC 60947-1 || IP40 housing)EN/IEC 60947-1 || IP20 terminals)EN/IEC 60947-1
|
Number Of Inputs
|
2 positive safety input 24 V DC 8 || 1 negative safety input
|
Product Or Component Type
|
safety module
|
Power Consumption In W
|
3 W 24 V DC
|
Safety Module Application
|
monitoring antivalent contacts || for emergency stop, guard and light curtain monitoring || monitoring of pressure-sensitive 4-wire protective devices
|
Power Consumption In Va
|
6.5 VA 24 V AC 50/60 Hz
|
Maximum Line Resistance
|
500 Ohm
|
Ambient Air Temperature For Storage
|
-25-85°C
|
Connections - Terminals
|
removable screw terminal block, 0.2...2.5 mm² solid or flexible || removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor || removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor || removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel || removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
|
[Ie] Rated Operational Current
|
5 A AC-1 for normally open relay contact || 3 A AC-15 for normally open relay contact || 5 A DC-1 for normally open relay contact || 3 A DC-13 for normally open relay contact || 3 A AC-1 for normally closed relay contact || 1 A AC-15 for normally closed relay contact || 3 A DC-1 for normally closed relay contact || 1 A DC-13 for normally closed relay contact
|
Safety Module Name
|
XPSUAT
|
[Ith] Conventional Free Air Thermal Current
|
16 A
|
Function Of Module
|
emergency stop button with 2 NC contacts || guard monitoring with 1 or 2 limit switches || monitoring 2 PNP sensors || magnetic switch monitoring || light curtain monitoring || RFID switch || monitoring of electro-sensitive protection equipment (ESPE) || sensing mat/edges || proximity sensor monitoring || monitoring 1 PNP + 1 NPN sensor
|
[Ui] Rated Insulation Voltage
|
250 V 2)EN/IEC 60947-1
|
Associated Fuse Rating
|
10 A gG NO relay output circuit IEC 60947-1
|
Type Of Start
|
automatic/manual/monitored
|
Maximum Response Time On Input Open
|
20 ms
|
Relative Humidity
|
5-95 % non-condensing
|
Number Of Outputs
|
4 on/off configurable pulsed output
|
Synchronisation Time Between Inputs
|
0.5 s || 2 s || 4 s
|
Auxiliary Contact Composition
|
1 NC configurable || 3 NO configurable || 3 NO immediate
|
Minimum Operating Temperature
|
-13 Degrees F
|
Maximum Operating Temperature
|
185 Degrees F
|
Safety Outputs
|
1 NC configurable; 3 NO configurable; 3 NO immediate
|
Rated Impulse Withstand Voltage
|
4 kV II IEC 60947-1
|
Rated Insulation Voltage
|
250 V 2)IEC 60947-1
|
Rated Operational Current
|
5 A AC-1 for normally open relay contact; 3 A AC-15 for normally open relay contact; 5 A DC-1 for normally open relay contact; 3 A DC-13 for normally open relay contact; 3 A AC-1 for normally closed relay contact; 1 A AC-15 for normally closed relay contact; 3 A DC-1 for normally closed relay contact; 1 A DC-13 for normally closed relay contact
|
Rated Supply Voltage
|
24 V AC - 15 to 10%; 24 V DC - 20 to 20%
|
Safety Inputs
|
2 positive safety input 24 V DC 8 mA; 1 negative safety input
|