Pressure Switch, Standard, SPST, 1/4 in NPT, 0 to 363 psi Range, Stainless Steel

  • Mfr # PN4223
  • Zoro # G6425964
product price: 
$
464.99
/ea
Free Shipping & Returns

Key Features

Action
Standard
Contact Form
SPST
Number of Pressure Connection Ports
1
Pressure Connection Type
1/4 in NPT
Range
0 to 363 psi
See all product information
Unlock 30-day payment terms
Unlock 30-day payment terms
Business customers can apply for Net 30—no fees, no interest, fast approval. Terms apply.
Create Account
Get 10% off your order
Get 10% off your order
Sign up for our email list and receive your promo code via email.

Specifications

Product Information

MFR #
PN4223
Zoro #
G6425964
UPC #
094720828617
Country of Origin
United States

Dimensions

Manufacturer Warranty Length
5 yr
Overall Depth
1.06 in
Overall Width
1.34 in
Overall Height
4.72 in

Details

Item
Pressure Switch
Action
Standard
Contact Form
SPST
Number of Pressure Connection Ports
1
Pressure Connection Type
1/4 in NPT
Range
0 to 363 psi
Housing Material
Stainless Steel
Temp. Range
13 Degrees to 176 Degrees F
On Set Point
4 to 363 psi
Off Set Point
2 to 362 psi
Process Connection
1/4 in FNPT
Burst Pressure
5,075 psi
Wetted Materials
Stainless Steel
IP Rating
IP65
Compatible With
Air and Liquids
Circuit Type
Triac
Output Current
2.5A @ 20 Degrees C
Electrical Connection
5-Pin 1/2 in UNF Connector
Pressure Switch Electrical Contact Form
SPST
Overload Protection
no
Pressure Switch Range
0 to 363 psi
Display
switching status LED, red function display 7-segment LED display measured values 7-segment LED display
Series
PN
Application
for industrial applications
Material
Stainless Steel
Voltage
265V AC
Product Type
Digital Pressure Sensor
Pressure rating
100 bar 1450 psi 10 Mpa
Min. bursting pressure
350 bar 5075 psi 35 MPa
Operating voltage tolerance [%]
5...10
Shock resistance
DIN IEC 68-2-27 50 g (11 ms)
Permanent current rating of switching output AC [mA]
250; ((...70°C) 1000 (...60°C) 1500 (...45°C) 2500 (...20°C))
Output function
normally open / normally closed; (parameterisable)
Hysteresis deviation [% of the span]
<± 0,1
Media
liquids and gases
MTTF [years]
224.58
Temperature coefficient zero point [% of the span / 10 K]
<± 0,2; (-25...80°C)
Measuring range
0...25 bar 0...363 psi 0...2.5 MPa
Long-term stability [% of the span]
<± 0,1; (per year)
Nominal voltage AC [V]
< 250
Reset point rP
0.1...24.9 bar 2...362 psi 0.01...2.49 MPa
Type of pressure
relative pressure
Delay time programmable dS, dr [s]
0, 0,2,...10, 11,...50
Short-circuit proof
no
Operating voltage [V]
85...265 AC
Set point SP
0.2...25 bar 4...363 psi 0.02...2.5 MPa
Reverse polarity protection
no
In steps of
0.1 bar 1 psi 0.01 MPa
Switch point accuracy [% of the span]
<± 1,0
Pressure Equipment Directive
Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Protection class
II
Damping process value dAP [s]
0...4
Number of digital outputs
1
Temperature coefficient span [% of the span / 10 K]
<± 0,3; (-25...80°C)
Switching frequency AC [Hz]
< 160
Protection
IP 65
Current consumption [mA]
< 10
Parameter setting options
hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit
Power-on delay time [s]
0.2
Max. voltage drop switching output AC [V]
2
Integrated watchdog
yes
Min. pressure cycles
100 million
Electrical design
Triac
Repeatability [% of the span]
<± 0,1; (with temperature fluctuations < 10 K)
Required protection
miniature fuse to IEC60127-2 sheet 1; ≤5 A; fast acting
Linearity deviation [% of the span]
<± 0,5
Min. insulation resistance [MΩ]
100; (500 V DC)
Restrictor element integrated
no (can be retrofitted)
Adjustment of the switch point
programming button
EMC
EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V
Total number of outputs
1
Number of inputs and outputs
Number of digital outputs: 1
Vibration resistance
DIN IEC 68-2-6 20 g (10...2000 Hz)
Pressure - Maximum
262 psi
Set Point - Maximum
363 psi
Compatible Media
Gas, Liquid
Reset Point - Minimum
2 psi
Pressure - Minimum
0 psi
Reset Point - Maximum
360 psi
Set Point - Minimum
4 psi
Voltage Rating - Maximum
250 V AC
Operating Temperature - Maximum
176 Degrees F
Electrical Design Output
Triac
Operating Temperature - Minimum
-13 Degrees F
Output Current Rating
2.5 A
Switching Signal Output
Triac
Current Rating
2.5 A
Switch Structure
SPST

Description

Digital Pressure Sensor, Power Required 45 to 65 Hz, 90 to 250V AC, Range 0 to 363 psi, Compatible With Air and Liquids, Circuit Type Triac, Output Current 2.5A @ 20 Degrees C, Contact Form 1NO/1NC, On Set Point 4 to 363 psi, Off Set Point 2 to 362 psi, Burst Pressure 5,075 psi, Process Connection 1/4 in FNPT, IP Rating IP65, Housing Material Stainless Steel, Wetted Materials Stainless Steel, Electrical Connection 5-Pin 1/2 in UNF Connector, Temp. Range 13 Degrees to 176 Degrees F

Ratings & reviews