Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, IEC 60335-1, RINA, GL, BV, UL, CSA, CCC, LROS, DNV, GOST, UKCA, THIEC 60068-2-30
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Electrical Durability
0.8 Mcycles (25 A, AC-1, Less than 440 V)
Switching Current
5 mA (Signalling Circuit)
Environmental Attributes
Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Signalling Circuit Frequency
25 to 400 Hz
Hold VA
7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Impulse Withstand Voltage
6 kV
Fuse Amps
10 A (Signalling Circuit), 40 A (Type 1 Power Circuit), 25 A (Type 2 Power Circuit)
Includes Protective Cover
Yes
Features
Without Built-In Suppressor Module
Rated Making Capacity
250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
Operating Time
12 to 22 ms (Closing), 4 to 19 ms (Opening)
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Overvoltage Category
CAT III
Operating Speed
3600 cycles per hr
Switching Voltage
17 V (Signalling Circuit)
Shock Resistance
15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Rated Breaking Capacity
250 A @ 440V
Mechanical Durability
15 Mcycles
Rated Insulation Volts
600/690V
Rated Short-Time Withstand Current
105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Control Circuit Voltage Limits
Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Application
Resistive Load
Mechanical Robustness
Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor open 10 Gn for 11 ms); Shocks contactor closed 15 Gn for 11 ms)
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Operating Altitude
0 to 9842.52 ft (0 to 3000 m)
Maximum Operating Rate
3600 cyc/h 140°F (60°C)
Control Circuit Type
AC 50/60 Hz
Pole Contact Composition
2 NO + 2 NC
Climatic Withstand
IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat
Control Circuit Voltage
110 V AC 50/60 Hz
Fire Resistance
1562°F (850°C) IEC 60695-2-1
Inrush Power in VA
70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Rated Operational Voltage
Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
Auxiliary Contacts Type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
Conventional Free Air Thermal Current
25 A (at 140°F (60°C)) for power circuit; 10 A (at 140°F (60°C)) for signalling circuit
Rated Operational Current
25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit
Protective Treatment
THIEC 60068-2-30
Heat Dissipation
2 to 3 W at 50/60 Hz
Utilisation Category
AC-1; AC-3; AC-3e; AC-4
Power Dissipation Per Pole
1.56 W AC-1
Full Load Current - Resistive
25 A
Full Load Current - Inductive
12:00 AM
Mounting Style
Plate, Rail
Maximum Operating Temperature
140 Degrees F
Maximum Voltage Rating
690V AC, 300V DC
Ambient Air Temperature For Operation
-40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating